Moslen M T, Kanz M F, Bhatia J, Catarau E M
Department of Pathology, University of Texas Medical Branch, Galveston 77550.
JPEN J Parenter Enteral Nutr. 1988 Nov-Dec;12(6):633-7. doi: 10.1177/0148607188012006633.
Materials and techniques are described for positioning and exteriorizing two chronic venous cannulas in the rat. A cannula for fluid infusion is placed in the inferior vena cava via the femoral vein and exteriorized on the tail, whereas a cannula for blood withdrawal is placed in the superior vena cava and exteriorized in the scapular region. Grooming behavior and range of motion are not impeded since the cannula used for chronic infusion is shielded by a light-weight tail cover instead of a torso harness. Application of this method can minimize numbers of rats used in total parenteral nutrition (TPN) studies as demonstrated by our feasibility study in which serum parameters of liver function were serially monitored in toxin-treated rats infused with nutrient mixtures.
本文描述了在大鼠体内定位并引出两根慢性静脉插管的材料和技术。一根用于输液的插管经股静脉置于下腔静脉,并引出至尾部;而一根用于采血的插管则置于上腔静脉,并引出至肩胛区域。由于用于慢性输液的插管由轻质尾套而非躯干束带保护,因此梳理行为和活动范围不受影响。正如我们的可行性研究所证明的,这种方法的应用可以减少全胃肠外营养(TPN)研究中使用的大鼠数量,在该研究中,对接受毒素处理并输注营养混合物的大鼠的肝功能血清参数进行了连续监测。