Many clinical toxicology laboratories receive urine specimens in urine cups that contain point of care (POC) drug testing strips. We conducted this study to evaluate the effect on the stability of commonly measured drugs in the clinical toxicology laboratory when urine is exposed to POC urine drug testing cups.
Drug free urine was spiked with 85 drugs that were measured by a validated liquid chromatography mass spectrometry (LCMS) method after exposure to POC urine drug testing cups at ambient and 2-6 °C temperatures. Alterations ≥20% were defined as significant changes in the drugs concentration.
Concentrations of amitriptyline, cyclobenzaprine, fentanyl, fluoxetine, flunitrazepam, nortriptyline, paroxetine, and sertraline were significantly reduced when urine specimens were stored inside POC urine drug testing cups for 24 h at ambient temperature. Storage of urine in urine chemistry dipsticks reduced the concentration of several drugs. When spiked urine was exposed to an increasing number of POC urine drug testing strips, the concentrations of some drugs were reduced in a dose-dependent manner. The drugs that were absorbed by POC urine drug testing strips were partially back extracted from the strips.
Exposure of urine specimens to POC urine drug testing strips reduces the concentration of several drugs measured by LCMS method.
许多临床毒理学实验室收到的尿液标本都装在含有即时检测(POC)药物检测条的尿杯中。我们进行这项研究是为了评估尿液暴露于 POC 尿液药物检测杯时对临床毒理学实验室中常用药物稳定性的影响。
在暴露于 POC 尿液药物检测杯后,将无药物的尿液与 85 种经验证的液相色谱-质谱(LCMS)方法测量的药物混合,在环境温度和 2-6°C 温度下。浓度变化≥20%被定义为药物浓度的显著变化。
当尿液标本在环境温度下储存在 POC 尿液药物检测杯内 24 小时时,阿米替林、环苯扎林、芬太尼、氟西汀、氟硝西泮、去甲替林、帕罗西汀和舍曲林的浓度明显降低。尿液化学试条储存尿液会降低几种药物的浓度。当尿液中添加的 POC 尿液药物检测条数量增加时,一些药物的浓度呈剂量依赖性降低。被 POC 尿液药物检测条吸收的药物部分从条上反萃取出来。
尿液标本暴露于 POC 尿液药物检测条会降低 LCMS 方法测量的几种药物的浓度。