Int J Oral Maxillofac Implants. 2019 Sep/Oct;34(5):1114-1120. doi: 10.11607/jomi.7129.
This in vitro study assessed the artifact production related to titanium and zirconia implants in cone beam computed tomography (CBCT) and compared the effect of different protocol settings on image quality for both materials.
A titanium implant and a zirconia implant were placed in a dry mandible. CBCT scans were obtained separately for each implant using the ProMax 3D (Planmeca) unit; 20 protocols were tested with varying kilovoltage (70 to 90 kVp) and resolution (high and low), and with and without a metal artifact reduction tool. Standard deviation and contrast-noise ratio were calculated in regions of interest adjacent and distant to the implant.
The zirconia produced more artifacts and its images were more affected by the different protocols than titanium. High kVps and an activated metal artifact reduction tool decreased the standard deviation values related to both implants. Activation of the metal artifact reduction tool also increased contrast-noise ratio values for both implants, whereas increasing kVp improved them only on titanium images. The standard deviation and contrast-noise ratio were not affected by resolution.
The zirconia implant generated more image artifacts than the titanium implant. Increasing kVp and the metal artifact reduction tool are efficient in decreasing the CBCT artifacts for both implants, whereas resolution does not affect their production.
本体外研究评估了锥形束计算机断层扫描(CBCT)中钛和氧化锆种植体相关的伪影产生,并比较了不同协议设置对两种材料图像质量的影响。
将钛种植体和氧化锆种植体分别放置在干燥的下颌骨中。使用 ProMax 3D(普兰梅卡)设备分别对每个种植体进行 CBCT 扫描;测试了 20 种不同的协议,包括不同的千伏值(70 至 90 kVp)和分辨率(高和低),以及是否使用金属伪影减少工具。在种植体相邻和远处的感兴趣区域计算标准偏差和对比噪声比。
氧化锆产生的伪影更多,其图像受不同协议的影响也大于钛。高千伏值和激活的金属伪影减少工具降低了与两种种植体相关的标准偏差值。激活金属伪影减少工具还增加了两种种植体的对比噪声比值,而增加千伏值仅改善了钛图像的对比噪声比值。分辨率不影响标准偏差和对比噪声比。
氧化锆种植体比钛种植体产生更多的图像伪影。增加千伏值和金属伪影减少工具可有效减少两种种植体的 CBCT 伪影,而分辨率不影响其产生。