Suppr超能文献

特短解剖型非骨水泥股骨柄与陶瓷对陶瓷关节面在特发性或乙醇诱导性股骨头坏死患者中的应用。

Ultra-Short Anatomic Uncemented Femoral Stem and Ceramic-on-Ceramic Bearing in Patients With Idiopathic or Ethanol-Induced Femoral Head Osteonecrosis.

机构信息

The Joint Replacement Center, Seoul Metropolitan SeoNam Hospital, Seoul, Republic of Korea.

The Joint Replacement Center, Ewha Womans University Seoul Hospital, Seoul, Republic of Korea.

出版信息

J Arthroplasty. 2020 Jan;35(1):212-218. doi: 10.1016/j.arth.2019.08.047. Epub 2019 Aug 28.

Abstract

BACKGROUND

Long-term result of the ultra-short anatomic cementless stem in the patients with idiopathic or ethanol-induced osteonecrosis of the femoral head has not been assessed. The aim of this study is to evaluate the long-term clinical, radiographic, computed tomography scan, and dual-energy X-ray absorptiometry scanning results, and survivorship of this specific femoral stem in patients with idiopathic or ethanol-induced femoral head osteonecrosis.

METHODS

Two hundred fifty-six patients (335 hips) with an average age of 49.8 years (range 20-63) were enrolled in the current study. All patients underwent dual-energy X-ray absorptiometry scanning of the acetabulum and proximal femur preoperatively and at final follow-up. Computed tomography scan was obtained in all patients at final follow-up. The mean follow-up was 14.7 years (range 13-16).

RESULTS

At final follow-up, the average Harris hip score, Western Ontario and McMaster Universities Osteoarthritis Index score, and University of California, Los Angeles activity score were 94 points, 12 points, and 8 points, respectively. Four stems (1%) underwent revision for aseptic loosening. One acetabular component (0.3%) was revised for recurrent dislocation. No hip was revised for squeaking or clicking sound. Survivorship of the femoral stem was 99.0% (95% confidence interval 94-100) and that of the acetabular component was 99.4% (95% confidence interval 95-100) at 14.7 years.

CONCLUSION

Ultra-short proximal loading anatomic uncemented femoral stems with ceramic-on-ceramic bearings have excellent survivorship free from aseptic loosening and good clinical results at long term.

LEVEL OF EVIDENCE

Level IV.

摘要

背景

超短解剖型非骨水泥股骨柄在特发性或乙醇诱导性股骨头坏死患者中的长期疗效尚未得到评估。本研究旨在评估该特定股骨柄在特发性或乙醇诱导性股骨头坏死患者中的长期临床、影像学、计算机断层扫描和双能 X 线吸收仪扫描结果及生存率。

方法

本研究纳入了 256 例(335 髋)患者,平均年龄为 49.8 岁(范围 20-63 岁)。所有患者术前及末次随访时均行髋臼和股骨近端双能 X 线吸收仪扫描,所有患者均在末次随访时行计算机断层扫描。平均随访时间为 14.7 年(范围 13-16 年)。

结果

末次随访时,平均 Harris 髋关节评分、西安大略和麦克马斯特大学骨关节炎指数评分和加利福尼亚大学洛杉矶分校活动评分分别为 94 分、12 分和 8 分。4 例(1%)因无菌性松动行翻修。1 例(0.3%)因髋臼假体反复脱位行翻修。无髋关节因弹响或喀喇音行翻修。股骨柄的 14.7 年生存率为 99.0%(95%置信区间 94%-100%),髋臼部件的生存率为 99.4%(95%置信区间 95%-100%)。

结论

超短型近端负荷解剖型非骨水泥股骨柄与陶瓷对陶瓷关节面具有良好的生存率,无无菌性松动,长期临床效果良好。

证据等级

IV 级。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验