Suppr超能文献

灵活扩孔器可在无需过度弯曲膝关节的情况下,与刚性扩孔器一样,创建出可比较的前交叉韧带重建股骨隧道:一项随机临床试验中对隧道形态的三维 CT 分析。

Flexible reamers create comparable anterior cruciate ligament reconstruction femoral tunnels without the hyperflexion required with rigid reamers: 3D-CT analysis of tunnel morphology in a randomised clinical trial.

机构信息

Exeter Knee Reconstruction Unit, Princess Elizabeth Orthopaedic Centre, Royal Devon and Exeter Hospital, Barrack Road, Exeter, EX2 5DW, Devon, UK.

Royal Devon and Exeter Hospital, Exeter, UK.

出版信息

Knee Surg Sports Traumatol Arthrosc. 2020 Jun;28(6):1971-1978. doi: 10.1007/s00167-019-05709-7. Epub 2019 Sep 21.

Abstract

PURPOSE

The hyperflexion required for femoral tunnel drilling in anterior cruciate ligament reconstruction can be challenging in patients with increased body habitus or musculature. Whilst allowing femoral tunnel creation without hyperflexion, additional benefits of flexible reamers have been proposed in terms of tunnel dimensions. The purpose of this study was to examine whether these theoretical benefits are seen in a clinical study.

METHODS

Fifty adult patients (with isolated anterior cruciate ligament rupture) were randomised to reconstruction with either flexible or rigid femoral reamers. Femoral tunnel drilling was performed at 100° flexion (flexible system) or maximal hyperflexion (rigid system). Otherwise, the procedure was standardised. Femoral tunnel measurements were performed by a consultant musculoskeletal radiologist who was blinded to the method of femoral drilling. Tunnel position, length and angles (axial and coronal) were measured alongside aperture shape and exit point using three-dimensional computed tomography 3-6 months post-operatively.

RESULTS

With no difference in tunnel position, tunnel length was found to increase with the use of the flexible system (37.8 ± 3.7 vs 35.0 ± 4.4 mm; p = 0.024). In addition, the exit point and fixation device were more anterior on the lateral femur using the flexible reamers (p = 0.016). No difference was seen in either tunnel angles or aperture shape. One case of incomplete posterior blow-out was seen in each of the study groups.

CONCLUSIONS

This comparative study shows that flexible reamers can reproduce a desired femoral tunnel position with only small improvements of no clinical relevance. As this can be achieved without hyperflexing the knee, these systems can be used for all patients (even when hyperflexion is a challenge).

LEVEL OF EVIDENCE

I.

摘要

目的

在前交叉韧带重建中,股骨隧道钻孔需要过度弯曲,这对于身材较高或肌肉发达的患者来说具有挑战性。虽然允许在不进行过度弯曲的情况下创建股骨隧道,但柔性扩孔器在隧道尺寸方面具有额外的优势。本研究的目的是检查这些理论优势是否在临床研究中得到体现。

方法

50 名成年患者(均有孤立性前交叉韧带断裂)被随机分为使用柔性或刚性股骨扩孔器进行重建的两组。股骨隧道钻孔在 100°弯曲(柔性系统)或最大过度弯曲(刚性系统)下进行。否则,手术过程标准化。由一位对股骨钻孔方法不知情的顾问肌肉骨骼放射科医生进行股骨隧道测量。术后 3-6 个月,使用三维计算机断层扫描(3D-CT)测量隧道位置、长度和角度(轴向和冠状),并同时测量孔径形状和出口点。

结果

在隧道位置无差异的情况下,发现使用柔性系统时隧道长度增加(37.8±3.7 比 35.0±4.4mm;p=0.024)。此外,使用柔性扩孔器时,出口点和固定装置在外侧股骨上更靠前(p=0.016)。在隧道角度或孔径形状方面没有差异。在研究组中,各有 1 例出现不完全的后爆裂。

结论

这项比较研究表明,柔性扩孔器可以在不进行过度弯曲的情况下复制所需的股骨隧道位置,仅略微改善,且无临床意义。由于可以在不进行过度弯曲的情况下实现这一点,因此这些系统可以用于所有患者(即使过度弯曲是一种挑战)。

证据水平

I。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验