Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
Indian J Ophthalmol. 2019 Oct;67(10):1663-1666. doi: 10.4103/ijo.IJO_24_19.
To ascertain if ultrasound (USG) B-scan examination of the optic nerve head (ONH) can be a useful tool to diagnose and quantify glaucomatous cupping.
A cross-sectional observational study of 48 eyes of 48 patients with clear ocular media and cup-disc ratio of (CDR) ≥0.6 were included. The disc was studied by + 90D examination, USG B-scan and ONH Optical coherence tomography (OCT) by three masked observers. Observer-1 assessed the clinical CDR, observer-2recordedopticcup diameter on USG B-scan and observer-3performed ONH OCT to note the software computed average CDR. Measurements of cupping obtained by these 3 methods were compared and their relative strengths determined. The interdependency between variables was further studied using regression analysis.
Clinically assessed disc ratios of 0.6, 0.7, 0.8, 0.9, and total corresponded to USG cup measures of 1.02 ± 0.11 mm, 1.23 ± 0.14 mm, 1.35 ± 0.072 mm, 1.45 ± 0.084 mm, 1.75 ± 0.15 mm and OCT average CDR of 0.62 ± 0.087, 0.68 ± 0.060, 0.75 ± 0.078, 0.81 ± 0.036, 0.89 ± 0.038, respectively. There was an excellent correlation between the three arms, with Pearson's co-efficient (r) of 0.87, P < 0.001 between clinical and USG cupping; r = 0.89, P < 0.001 between clinical and OCT cupping; and r = 0.88, P < 0.001 between USG and OCT cupping. A relation of y = 1.64x + 0.03 was obtained between them, where y stands for USG cup diameter and x stands for the observed clinical CDR.
Ultrasonographic measurement of optic cup diameter corresponds well to clinical ONH cupping. Therefore, it can reliably be used in quantifying ONH cupping in cases of media opacities which preclude optic disc visualization.
确定视神经头(ONH)的超声(USG)B 扫描检查是否可作为诊断和定量青光眼杯状凹陷的有用工具。
对 48 例眼内透明介质和杯盘比(CDR)≥0.6 的患者的 48 只眼进行了横断面观察性研究。通过+90D 检查、USG B 扫描和 ONH 光相干断层扫描(OCT)对视盘进行研究,由 3 名掩蔽观察者进行。观察者 1 评估临床 CDR,观察者 2 记录 USG B 扫描上的视杯直径,观察者 3 进行 ONH OCT 以记录软件计算的平均 CDR。通过这 3 种方法获得的杯状凹陷测量值进行了比较,并确定了它们的相对强度。进一步使用回归分析研究变量之间的相互依赖性。
临床评估的 0.6、0.7、0.8、0.9 和总比值分别对应于 USG 杯测量值 1.02±0.11mm、1.23±0.14mm、1.35±0.072mm、1.45±0.084mm 和 1.75±0.15mm,以及 OCT 平均 CDR 为 0.62±0.087、0.68±0.060、0.75±0.078、0.81±0.036、0.89±0.038。这三个分支之间存在极好的相关性,Pearson 相关系数(r)分别为 0.87(P<0.001),临床和 USG 杯状凹陷之间;r=0.89(P<0.001),临床和 OCT 杯状凹陷之间;以及 r=0.88(P<0.001),USG 和 OCT 杯状凹陷之间。它们之间获得了关系 y=1.64x+0.03,其中 y 代表 USG 杯直径,x 代表观察到的临床 CDR。
视神经杯直径的超声测量与临床 ONH 杯状凹陷吻合良好。因此,在不能观察视盘的介质混浊的情况下,它可以可靠地用于定量 ONH 杯状凹陷。