Laborde F, Lecompte Y, Bex J P
Presse Med. 1985 Jan 26;14(3):157-9.
The results of aortic valve replacement in the acute phase of valvular endocarditis are dependent upon the degree of destruction by sepsis of the left ventricle-aorta junction. The stability of the prosthesis installed is conditioned by the extent of the lesion. Numerous techniques have been described to maintain the prosthesis firmly in place. In the technique reported here, the prosthesis is implanted in the usual position, but the sutures are tied outside the heart. Depending on the site of the lesion, this is done by opening the left atrium or the infundibulum of the right ventricle, and by passing the stitches through the aortic wall. This quick and simple technique ensures good stability of the prosthesis.
在感染性心内膜炎急性期进行主动脉瓣置换的结果取决于左心室-主动脉连接处因败血症而被破坏的程度。所安装假体的稳定性取决于病变的范围。已经描述了许多技术来将假体牢固地固定到位。在此报告的技术中,假体植入通常位置,但缝线在心脏外部打结。根据病变部位,通过打开左心房或右心室漏斗部,并将缝线穿过主动脉壁来完成。这种快速简单的技术可确保假体具有良好的稳定性。