储存溶液类型及长时间储存对细胞免疫反应性的影响

Effects of the Storage Solution Type and Prolonged Storage on the Immunoreactivity of Cells.

作者信息

Ikeda Katsuhide, Sato Shouichi, Chigira Hiroshi, Shibuki Yasuo, Hiraoka Nobuyoshi

机构信息

Department of Medical Technology and Sciences, School of Health Sciences at Narita, International University of Health and Welfare, Narita, Japan,

Department of Medical Technology and Sciences, School of Health Sciences at Narita, International University of Health and Welfare, Narita, Japan.

出版信息

Acta Cytol. 2020;64(4):352-359. doi: 10.1159/000503268. Epub 2019 Oct 9.

Abstract

INTRODUCTION

In effusion cytology, immunocytochemistry is a useful staining approach to provide important information for diagnosis. Effusion cytology is performed not only for pleural effusions and ascites but also for peritoneal and needle washing from fine needle aspirations or instruments. Although various solutions are used for washing cytology, the effect of the solution type on immunocytochemical reactivity is not fully understood. In this study, we examined the immunocytochemical reactivity of cytological samples after storage in various solutions.

METHODS

Cell block specimens were obtained from ascites of patients with peritoneal cancer and pleural effusions of patients with diffuse malignant mesothelioma. Various solutions, including physiological saline (PS), Ringer solution, a low-molecular-weight dextran L injection, Voluven 6% solution, Mixid L injection, RPMI-1640 medium, and horse serum were added to the sediment layers of aliquots. All samples were kept at 4°C, and aliquots were subsequently processed at specific time points (0, 1, 2, 4, 7, and 14 days). Formalin-fixed, paraffin-embedded, cell block samples were prepared for immunocytochemical staining. Immunocytochemical results were analyzed for differences in the percentages of positive cells, using the effusion sample stored for 1 h as standard (100%).

RESULTS

For all solutions other than PS, the median and central 50% of values were <100% (with respect to the effusion sample as a standard) after 1 h of storage. Immunoreactivity decreased for most solutions as time progressed.

CONCLUSION

Of note, immunocytochemistry results obtained using a washing solution are different from those using an effusion sample. For cytology, when a washing solution was used or when a sample was stored for a long time, the accuracy of the immunocytochemical results was low.

摘要

引言

在积液细胞学中,免疫细胞化学是一种有用的染色方法,可为诊断提供重要信息。积液细胞学不仅用于胸腔积液和腹水,还用于细针穿刺或器械获取的腹腔积液和针吸冲洗液。尽管有多种溶液用于冲洗细胞学检查,但溶液类型对免疫细胞化学反应性的影响尚未完全了解。在本研究中,我们检测了细胞学样本在各种溶液中储存后的免疫细胞化学反应性。

方法

细胞块标本取自腹膜癌患者的腹水和弥漫性恶性间皮瘤患者的胸腔积液。将各种溶液,包括生理盐水(PS)、林格溶液、低分子右旋糖酐L注射液、万汶6%溶液、米喜定L注射液、RPMI-1640培养基和马血清,加入到等分试样的沉淀层中。所有样本均保存在4°C,随后在特定时间点(0、1、2、4、7和14天)进行处理。制备福尔马林固定、石蜡包埋的细胞块样本用于免疫细胞化学染色。以储存1小时的积液样本为标准(100%),分析免疫细胞化学结果中阳性细胞百分比的差异。

结果

除PS外,所有溶液在储存1小时后,中位数和中间50%的值均<100%(以积液样本为标准)。随着时间的推移,大多数溶液的免疫反应性降低。

结论

值得注意的是,使用冲洗液获得的免疫细胞化学结果与使用积液样本的结果不同。对于细胞学检查,当使用冲洗液或样本长时间储存时,免疫细胞化学结果的准确性较低。

相似文献

2
Characterizing the Effect of Automated Cell Sorting Solutions on Cytomorphological Changes.
Acta Cytol. 2020;64(3):232-240. doi: 10.1159/000500769. Epub 2019 Jun 24.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验