Boudreau Nicolas, Brochu Felix-Olivier, Dubreuil Louis-Michel, Laurendeau Thierry, Leblanc Olivier, De Vette Emmanuelle, Tousignant-Laflamme Yannick
École de Réadaptation, Faculté de Médecine et des Sciences de la Santé, Université de Sherbrooke, Sherbrooke, QC, Canada.
Centre de Recherche du Centre Hospitalier Universitaire de Sherbrooke, Sherbrooke, QC, Canada.
J Back Musculoskelet Rehabil. 2020;33(4):685-692. doi: 10.3233/BMR-181184.
Recent technologies, such as the iPod, are often equipped with an accelerometer and magnetometer, which, through software applications, can perform various inclinometric functions. These applications have the potential to measure and quantify range of motion (ROM).
The purpose of this study was to estimate the iPod "Gyroscope" application intra- and inter-rater reliability as well as its criterion validity in healthy participants lumbar ROM assessment.
The sample consisted of 29 healthy participants. For the estimation of intra- and inter-reliability, two examiners measured the lumbar ROM of each participant twice using the iPod. To estimate the criterion validity, the measures were compared to those obtained with the Back Range of Motion Device (BROM; lateral flexion) and the double inclinometer (flexion and extension). Reliability and validity were then established using the intraclass correlation coefficient (ICC).
We observed a moderate to high intra-rater reliability (ICCs = 0.67-0.91) and a moderate to high inter-rater reliability for each movement (ICCs = 0.72-0.89). For the criterion validity, the ICCs were all high (ICCs = 0.65-0.89).
Our results provide evidence that the iPod "Gyroscope" application can be used to assess lumbar ROM for all movements.
诸如iPod等最新技术通常配备有加速度计和磁力计,通过软件应用程序,它们能够执行各种测斜功能。这些应用程序有潜力测量和量化运动范围(ROM)。
本研究旨在评估iPod“陀螺仪”应用程序在健康受试者腰椎ROM评估中的评分者内和评分者间信度及其效标效度。
样本包括29名健康受试者。为评估评分者内和评分者间信度,两名检查者使用iPod对每位受试者的腰椎ROM测量两次。为评估效标效度,将测量结果与使用背部运动范围测量仪(BROM;侧屈)和双倾角仪(屈伸)获得的结果进行比较。然后使用组内相关系数(ICC)确定信度和效度。
我们观察到每位检查者的评分者内信度为中等至高(ICC = 0.67 - 0.91),各动作的评分者间信度为中等至高(ICC = 0.