A 69-year-old woman with diabetes was found to have multi-vessel coronary artery disease and underwent 5-vessel coronary artery bypass grafting. Patient had persistent cardiogenic shock postoperatively despite intra-aortic balloon pump and escalating pressor requirements. Electrocardiogram showed new ischemic changes and the patient was urgently taken to the catheterization lab for coronary angiography and placement of an Impella CP for higher degree of hemodynamic support via the left femoral artery. Due to limitations in vascular access the Impella CP sheath was utilized for vascular access for diagnostic angiography and coronary intervention concurrently with ongoing Impella CP support. The first obtuse marginal had severe proximal disease and was treated with percutaneous coronary intervention (PCI) with a drug eluting stent. To our knowledge, this case is the first in which successful diagnostic angiography as well as multi-vessel PCI was performed via an Impella sheath while concurrently using the percutaneous mechanical circulatory support system of the Impella CP. Multiple guide catheters and a pigtail catheter were successfully passed via the Impella CP sheath to perform PCI. This novel method of vascular access could be an important tool to use in high-risk patients with limitations in access sites and decrease potential bleeding complications by limiting the number of arterial punctures.

摘要

一位 69 岁的糖尿病女性患者被发现患有多支冠状动脉疾病,并接受了 5 支冠状动脉旁路移植术。尽管使用了主动脉内球囊泵并逐渐增加升压药的使用,但患者术后仍持续出现心源性休克。心电图显示出新的缺血性改变,患者紧急被送往导管室进行冠状动脉造影,并通过左股动脉放置 Impella CP 以提供更高程度的血流动力学支持。由于血管通路受限,Impella CP 鞘用于血管通路以进行诊断性血管造影和冠状动脉介入治疗,同时持续进行 Impella CP 支持。第一钝缘支有严重的近端病变,经皮冠状动脉介入治疗(PCI)和药物洗脱支架治疗。据我们所知,这是首例成功通过 Impella 鞘进行诊断性血管造影和多支 PCI 的病例,同时使用了 Impella CP 的经皮机械循环支持系统。多个引导导管和猪尾导管成功地通过 Impella CP 鞘进行 PCI。这种新的血管通路方法可能是一种重要的工具,可用于存在血管通路受限的高危患者,并通过限制动脉穿刺次数来减少潜在的出血并发症。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验