Suppr超能文献

药物洗脱支架和裸金属支架的体外血栓形成。

In vitro thrombogenicity of drug-eluting and bare metal stents.

机构信息

Polo Cardio-Toraco Vascolare, Policlinico S. Orsola, Bologna, Italy.

Department of Experimental, Diagnostic and Specialty Medicine, Alma Mater Studiorum, University of Bologna, Italy.

出版信息

Thromb Res. 2020 Jan;185:43-48. doi: 10.1016/j.thromres.2019.11.016. Epub 2019 Nov 14.

Abstract

AIMS

We sought to investigate the thrombogenicity of different DES and BMS in an in vitro system of stent perfusion.

MATERIAL AND METHODS

The experimental model consisted of a peristaltic pump connected to 4 parallel silicone tubes in which different stents were deployed. Blood was drawn from healthy volunteers and the amount of stent surfaced-induced thrombus deposition was determined using I-fibrinogen.

RESULTS

Compared to Resolute, Biomatrix and Vision, Xience was associated with the lowest amount of stent surface-induced thrombus formation, with a significant difference compared to Vision (I-fibrinogen median value deposition [IQ range]: 50 ng [25-98] versus 560 ng [320-1520], respectively, p < 0.05), but not to other DES. In the second set of experiments Fluoropolymer-coated BMS not eluting drug was associated with a significant 3-fold reduction in I-fibrinogen deposition (245 ng [80-300]) compared to Vision (625 ng [320-760], p < 0.05), but a 7-fold increase compared to Xience (35 ng [20-60], p < 0.05). Finally Xience was associated with a significantly greater absorption of albumin compared to BMS.

CONCLUSIONS

In an in vitro system of stent perfusion, Xience was associated with the lowest amount of stent surface-induced thrombus formation compared with Resolute, Biomatrix and Vision, with a noted synergistic effect between the fluoropolymer and the drug.

摘要

目的

我们旨在通过体外支架灌注系统研究不同 DES 和 BMS 的血栓形成性。

材料和方法

实验模型由蠕动泵连接到 4 个平行的硅酮管组成,其中部署了不同的支架。从健康志愿者中抽取血液,并使用 I-纤维蛋白原测定支架表面诱导血栓沉积的量。

结果

与 Resolute 相比,Xience 与 Biomatrix 和 Vision 相比,与最低量的支架表面诱导血栓形成相关,与 Vision 相比差异具有统计学意义(I-纤维蛋白原沉积中位数[IQ 范围]:50ng[25-98]与 560ng[320-1520],p<0.05),但与其他 DES 无差异。在第二组实验中,涂氟聚合物的 BMS 不洗脱药物与 I-纤维蛋白原沉积的显著减少(245ng[80-300])相关,与 Vision(625ng[320-760])相比差异具有统计学意义(p<0.05),但与 Xience(35ng[20-60])相比增加了 7 倍,差异具有统计学意义(p<0.05)。最后,Xience 与 BMS 相比,白蛋白的吸收量显著增加。

结论

在体外支架灌注系统中,与 Resolute、Biomatrix 和 Vision 相比,Xience 与最低量的支架表面诱导血栓形成相关,氟聚合物和药物之间存在协同作用。