Suppr超能文献

一种用于测定八名亚洲患者血清氯唑西林的简单高效液相色谱法。

A simple high-performance liquid chromatography method for measuring serum cloxacillin in eight Asian patients.

作者信息

Lee H S, Ti T Y, Khoo Y M

机构信息

Department of Pharmacology, Faculty of Medicine, National University of Singapore.

出版信息

Ther Drug Monit. 1988;10(3):340-4. doi: 10.1097/00007691-198803000-00018.

Abstract

A simple reversed-phase high-performance liquid chromatography method using probenecid as internal standard was used for the quantitation of serum cloxacillin in eight Asian patients. The method does not require the extraction of the antibiotic from serum and the percentage recovery of cloxacillin was 96-103%. The presence of ampicillin, fusidic acid, benzylpenicillin, and gentamicin in serum appeared not to interfere with the method. The day-to-day coefficient of variation of the method over 6 months for 4-120 micrograms/ml ranged between 6.2 and 11.5%. In the eight patients in whom cloxacillin was administered intravenously or orally, there was great interindividual and intra-individual variation in the serum concentrations attained. The highest concentration of 85 micrograms/ml was obtained in a sample taken 1.5 h after an intravenous dose of 1 g. The lowest concentration of less than 1 microgram/ml was from a sample taken 6 h after an oral dose of 500 mg.

摘要

采用以丙磺舒为内标的简单反相高效液相色谱法对8例亚洲患者的血清氯唑西林进行定量分析。该方法无需从血清中提取抗生素,氯唑西林的回收率为96% - 103%。血清中氨苄西林、夫西地酸、苄青霉素和庆大霉素的存在似乎不干扰该方法。该方法在6个月内对4 - 120微克/毫升的日间变异系数在6.2%至11.5%之间。在8例静脉或口服氯唑西林的患者中,所达到的血清浓度存在很大的个体间和个体内差异。静脉注射1克后1.5小时采集的样本中,最高浓度为85微克/毫升。口服500毫克后6小时采集的样本中,最低浓度低于1微克/毫升。