Suppr超能文献

下肢肌间隔弹性的无创测量在急性间隔综合征中的应用:与压力相关的超声的临床结果。

Non-invasive measurement of muscle compartment elasticity in lower limbs to determine acute compartment syndrome: Clinical results with pressure related ultrasound.

机构信息

Department of Orthopaedic Trauma, Sana Klinikum Offenbach, Offenbach am Main, Germany; Department of Orthopaedic Trauma and Reconstructive Surgery, University of Aachen Medical Center, Aachen, Germany.

Department of Orthopaedic Trauma, Sana Klinikum Offenbach, Offenbach am Main, Germany.

出版信息

Injury. 2020 Feb;51(2):301-306. doi: 10.1016/j.injury.2019.11.027. Epub 2019 Nov 21.

Abstract

PURPOSE

Close monitoring of patients at risk to develop an acute compartment syndrome (ACS) is well known to be essential. There is a relevant risk that clinical assessment alone is not reliable enough. Reliable assessment of the elasticity of the muscle compartment might represent a helpful tool to assess the pressure in this enclosed space. Therefore, the purpose of this study was to determine the feasibility of muscle elasticity measurements by a non-invasive device.

METHODS

In a prospective study, patients with elevated intra-compartmental pressure (ICP) were included. An ultrasound-based measurement approach was used to determine the relative elasticity (RE) of both, the affected and unaffected limb. A pressure transducing ultrasonic probe head was combined with the probe to obtain cross section views of the anterior tibial compartment and to detect the observer´s amount of pressure applied on the limb surface. The compartment depth without compression (P) corresponds to 100%. The difference to the compartment depth with a probe pressure of 80mmHg (P) on the limb (delta) related to P resulted in a value of relative elasticity (%). These values were compared with the invasive needle measurement (mmHg) regarding their intra-individual difference and correlation of the compartmental pressure.

RESULTS

In six trauma patients the relative elasticity in their paired limbs showed a significant difference. The RE in the healthy compartments revealed a level of 17.95% (SD+/-5,4), whereas the RE of the affected limbs significantly decreased to a mean of 5,14% (SD+/-2,1) (p < 0,0001). The average values of the repetitively measured RE and the ICP showed a high level of correlation (spearman correlation coefficient: roh = 0,929). The RE less than 10,5% of the anterior tibial compartment had a sensitivity of 95,8% and a specificity of 87,5% to an appropriate diagnosis of ACS.

DISCUSSION

The presented study appears to represent a promising approach to reliably assess the pressure in a muscle compartment. In this first clinical study, our measurement method represents a low cost, easy and secure approach that has the potential to substitute invasive measurement. Further investigations and development in lager cohorts are required to improve its practicality and to confirm the reliability.

摘要

目的

众所周知,密切监测有发生急性间隔综合征(ACS)风险的患者至关重要。仅通过临床评估,其可靠性可能存在不足。可靠地评估肌肉间隔的弹性可能是评估该封闭空间内压力的有用工具。因此,本研究旨在确定一种非侵入性设备测量肌肉弹性的可行性。

方法

在一项前瞻性研究中,纳入了有升高的肌间隔内压(ICP)的患者。采用基于超声的测量方法来确定受影响和未受影响肢体的相对弹性(RE)。将压力传感器超声探头头与探头相结合,以获得胫骨前间隔的横截面视图,并检测观察者施加在肢体表面的压力。无压迫时的间隔深度(P)对应于 100%。与肢体上施加 80mmHg 探头压力时的间隔深度(P)的差值(delta)与 P 相关,从而得到相对弹性(%)的值。将这些值与侵入性针测量(mmHg)进行比较,以评估其个体内差异和隔间压力的相关性。

结果

在 6 例创伤患者中,配对肢体的相对弹性存在显著差异。健康间隔的 RE 显示为 17.95%(标准差+/-5.4),而受影响肢体的 RE 显著降低至 5.14%(标准差+/-2.1)(p<0.0001)。重复性测量的 RE 和 ICP 的平均数值显示出高度相关性(Spearman 相关系数:rho=0.929)。RE 小于胫骨前间隔的 10.5%,对 ACS 的诊断具有 95.8%的敏感性和 87.5%的特异性。

讨论

本研究似乎代表了一种可靠评估肌肉间隔压力的有前途的方法。在这项首次临床研究中,我们的测量方法是一种低成本、简便且安全的方法,具有替代侵入性测量的潜力。需要进一步的研究和更大队列的开发,以提高其实用性并确认其可靠性。