Suppr超能文献

"单指和双指阴道触诊最大自主收缩的内部和外部评估者间可靠性比较,以及与 Peritron 测压计的结构效度"。

"Comparative intra- and inter-rater reliability of maximal voluntary contraction with unidigital and bidigital vaginal palpation and construct validity with Peritron manometer".

机构信息

Women's Health Research Laboratory, Physical Therapy Department, Federal University of São Carlos, São Carlos, São Paulo, Brazil.

Preventive Physical Therapy and Ergonomics Laboratory, Physical Therapy Department, Federal University of São Carlos, São Carlos, São Paulo, Brazil.

出版信息

Neurourol Urodyn. 2020 Feb;39(2):721-731. doi: 10.1002/nau.24263. Epub 2019 Dec 24.

Abstract

AIMS

Evaluate the intra- and inter-rater reliability of maximal voluntary contraction (MVC) of pelvic floor muscle (PFM) assessment by unidigital and bidigital vaginal palpation. As a secondary aim, evaluate the construct validity of vaginal palpation and a manometer.

METHODS

A total of 120 women were recruited and allocated into three groups according to age (group 1 [G1]: 18-35; G2: 36-59; G3: ≥60 years). Examiner A conducted an interview and examiners B and C performed evaluations of PFM function using both unidigital and bidigital vaginal palpation. Seven to 10 days later, examiner B repeated both types of vaginal palpation and measured the MVC pressure with a Peritron. Reliability was analyzed using Cohen's linear weighted Kappa (κ ). The construct validity was calculated using the Spearman's correlation (r ).

RESULTS

Intra-rater reliability of unidigital and bidigital palpation was κ  = 0.75 and κ  = 0.58 in G1, κ  = 0.59 and κ  = 0.73 in G2, and κ  = 0.79 and κ  = 0.86 in G3, respectively. Inter-rater reliability of unidigital and bidigital palpation was κ  = 0.52 and κ  = 0.48 in G1, κ  = 0.47 and κ  = 0.52 in G2, and κ  = 0.50 and κ  = 0.64 in G3, respectively. Spearman's correlation coefficients were significant at r  = 0.79 and r  = 0.80 for unidigital and bidigital vaginal palpation, respectively.

CONCLUSIONS

Unidigital or bidigital vaginal palpation were indicated to evaluate G1 and G2 but bidigital palpation was more reliable in G3 when two examiners performed the evaluation. For the assessment conducted by one examiner, unidigital palpation was more reliable in G1 while bidigital palpation was more reliable in G2 and G3. Both unidigital and bidigital palpation have high measures of validity.

摘要

目的

评估单指和双指阴道触诊评估盆底肌(PFM)最大自主收缩(MVC)的组内和组间可靠性。作为次要目的,评估阴道触诊和测压计的结构效度。

方法

共招募了 120 名女性,并根据年龄分为三组(G1:18-35 岁;G2:36-59 岁;G3:≥60 岁)。检查者 A 进行了访谈,检查者 B 和 C 使用单指和双指阴道触诊对 PFM 功能进行了评估。7-10 天后,检查者 B 重复了两种类型的阴道触诊,并使用 Peritron 测量 MVC 压力。使用 Cohen 的线性加权 Kappa(κ)分析可靠性。使用 Spearman 相关系数(r)计算结构效度。

结果

单指和双指触诊的组内可靠性在 G1 中分别为 κ=0.75 和 κ=0.58,在 G2 中分别为 κ=0.59 和 κ=0.73,在 G3 中分别为 κ=0.79 和 κ=0.86。单指和双指触诊的组间可靠性在 G1 中分别为 κ=0.52 和 κ=0.48,在 G2 中分别为 κ=0.47 和 κ=0.52,在 G3 中分别为 κ=0.50 和 κ=0.64。单指和双指阴道触诊的 Spearman 相关系数分别为 r=0.79 和 r=0.80,均具有统计学意义。

结论

当由两名检查者进行评估时,单指或双指阴道触诊可用于评估 G1 和 G2,但在 G3 中双指触诊更可靠。对于由一名检查者进行的评估,在 G1 中单指触诊更可靠,而在 G2 和 G3 中双指触诊更可靠。单指和双指触诊均具有较高的有效性。