Miniature "soft gel" filled breast prostheses were implanted into rats, and half of these were purposefully ruptured upon insertion. At sacrifice of the animals later, the position of the exuded gel, the variability of the capsule thickness, and the extent of the capsule formation were evaluated. The capsule thickness was significantly increased around the ruptured prostheses, in response to the exuded gel. Also, the gel migrated through the fibrous capsule and into the surrounding tissue, eliciting an inflammatory response there to produce capsule thickening.
将微型“软凝胶”填充乳房假体植入大鼠体内,其中一半在植入时故意使其破裂。在随后处死动物时,评估渗出凝胶的位置、包膜厚度的变异性以及包膜形成的程度。由于渗出的凝胶,破裂假体周围的包膜厚度显著增加。此外,凝胶穿过纤维包膜迁移到周围组织,在那里引发炎症反应,导致包膜增厚。