Kappel Andreas, Mortensen Jacob Fyhring, Nielsen Poul Torben, Odgaard Anders, Laursen Mogens
Orthopaedic Research Unit, Aalborg University Hospital, Aalborg, Denmark; Department of Clinical Medicine, Aalborg University, Aalborg, Denmark.
Department of Orthopedic Surgery, Copenhagen University Hospital Herlev-Gentofte, Hellerup, Denmark.
Knee. 2020 Jan;27(1):221-228. doi: 10.1016/j.knee.2019.09.013. Epub 2019 Dec 23.
Stress radiography is used in the valuation of soft tissue laxity following total knee arthroplasty (TKA). However, reliability and agreement is largely unknown.
In this prospective reliability study, we included 15 participants with prior TKA. Standardized coronal stress radiographs were obtained in both extension and flexion and with both varus and valgus stress. All radiographs were repeated (test-retest). In extension the Telos stress device was used, and flexion radiographs were obtained using the epicondylar-view. Three independent raters measured angulation between femoral and tibial component from all radiographs. Reliability was assessed by intra-class correlation coefficient (ICC) and agreement visualized with Bland-Altman plots and by mean difference and limits of agreement (LOA).
Stress radiography in extension showed excellent reliability with ICC = 0.96 (0.95-0.98) and LOA of ±1.2°. Stress radiography at 80-90° of flexion showed good to excellent reliability when measuring medial laxity with ICC = 0.94 (0.89-0.97) and LOA of ±1.7°; however, when measuring lateral laxity the reliability was only moderate to good with ICC = 0.70 (0.51-0.84) and LOA of ±6.3°.
Stress radiography is clinically applicable and the methods described in this study provide excellent reliability for measurement of laxity in extension. The reliability of measurements in flexion is good to excellent when measuring medial laxity but only moderate to good when measuring lateral laxity.
应力位X线摄影用于评估全膝关节置换术(TKA)后软组织松弛情况。然而,其可靠性和一致性在很大程度上尚不清楚。
在这项前瞻性可靠性研究中,我们纳入了15例既往接受过TKA的参与者。在伸直和屈曲位以及内翻和外翻应力下均获取标准化的冠状位应力位X线片。所有X线片均重复拍摄(重测)。伸直位使用Telos应力装置,屈曲位X线片采用髁上视图获取。三名独立的评估者测量了所有X线片中股骨和胫骨假体组件之间的成角情况。通过组内相关系数(ICC)评估可靠性,并使用Bland-Altman图以及平均差异和一致性界限(LOA)直观显示一致性。
伸直位应力位X线摄影显示出极佳的可靠性,ICC = 0.96(0.95 - 0.98),LOA为±1.2°。在80 - 90°屈曲位测量内侧松弛时,应力位X线摄影显示出良好至极佳的可靠性,ICC = 0.94(0.89 - 0.97),LOA为±1.7°;然而,在测量外侧松弛时,可靠性仅为中等至良好,ICC = 0.70(0.51 - 0.84),LOA为±6.3°。
应力位X线摄影在临床上是适用的,本研究中描述的方法在测量伸直位松弛时具有极佳的可靠性。在测量屈曲位松弛时,测量内侧松弛的可靠性良好至极佳,但测量外侧松弛时仅为中等至良好。