Suppr超能文献

在代谢健康志愿者中静脉注射和皮下注射生物合成人胰岛素原后的药代动力学。

Pharmacokinetics of biosynthetic human proinsulin following intravenous and subcutaneous administration in metabolically healthy volunteers.

作者信息

Zilker T R, Gray I P, Hales C N, Wahl K, Ermler R, Lebender A, Heinzel G, Bottermann P

机构信息

II. Medizinische Klinik der Technischen Universität München, Germany.

出版信息

Horm Metab Res Suppl. 1988;18:37-43.

PMID:3192159
Abstract

40 pmol of biosynthetic human proinsulin was administered to 8 healthy volunteers by intravenous and by subcutaneous route. Following proinsulin administration, venous blood was collected in regular intervals within which proinsulin was determined by a specific radioimmunometric assay with monoclonal antibodies. The proinsulin concentration was determined simultaneously with the insulin and C-peptide radioimmunoassay. Through this investigation the following kinetic parameters were found: The kinetics of the biosynthetic human proinsulin can be best described by the 3-compartment model. The dominant biological half-life was 92 minutes. In intravenous proinsulin administration a proinsulin mean transit time of 80 minutes was found, whereas in subcutaneous administration a proinsulin retention time of 225 minutes was measured. The mean resorption velocity of the subcutaneously applied proinsulin amounted to 145 minutes. Two lag times for subcutaneous resorption can be described, a short one with 9.4 minutes and a long one with 65 minutes. The initial distribution volume for proinsulin was 3.8 l, whereas the distribution volume after complete distribution was 9.3 l. The mean total metabolic clearance was determined with 120 ml/min. Since no difference for the proinsulin concentration was found using the 3 different determination methods a peripheral proinsulin conversion to insulin and C-peptide is not likely. The basal endogenous secretion rate for proinsulin is 68.7 pmol per hour.

摘要

将40皮摩尔生物合成人胰岛素原通过静脉和皮下途径给予8名健康志愿者。给予胰岛素原后,定期采集静脉血,通过单克隆抗体特异性放射免疫测定法测定其中的胰岛素原。同时通过胰岛素和C肽放射免疫测定法测定胰岛素原浓度。通过这项研究发现了以下动力学参数:生物合成人胰岛素原的动力学可用三室模型最佳描述。主要生物半衰期为92分钟。静脉注射胰岛素原时,胰岛素原平均通过时间为80分钟,而皮下注射时,胰岛素原保留时间为225分钟。皮下应用胰岛素原的平均吸收速度为145分钟。皮下吸收可描述为两个延迟时间,短的为9.4分钟,长的为65分钟。胰岛素原的初始分布容积为3.8升,而完全分布后的分布容积为9.3升。平均总代谢清除率测定为120毫升/分钟。由于使用3种不同测定方法未发现胰岛素原浓度有差异,因此外周胰岛素原转化为胰岛素和C肽的可能性不大。胰岛素原的基础内源性分泌率为每小时68.7皮摩尔。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验