Wongsiri Sunton, Liawrungrueang Wongthawat
Department of Orthopaedic Surgery, Faculty of Medicine, Prince of Songkla University, Hat Yai, Thailand.
Adv Orthop. 2020 Jan 4;2020:6273723. doi: 10.1155/2020/6273723. eCollection 2020.
The standard open technique for carpal tunnel surgery has wound problems and complications significantly more than minimally invasive surgery using the Wongsiri technique with MiniSURE Kit® (Surgical Innovation Healthcare Co., Ltd, Bangkok, Thailand) and in particular, the open technique surgery requires a longer time for return to work. CTR surgery with endoscopic devices improves the results with fewer wound problems when compared with the commonly used open technique; however, nerve complications and injury are more prevalent with endoscopic surgery than with the open technique. The Wongsiri technique produces good results with new medical devices such as the MiniSURE View, for improved vision and line-of-sight, and the MiniSURE Cut for improved and complete cutting via the supraretinacular technique that may reduce the nerve problems associated with endoscopic tooling in the carpal tunnel.
To evaluate the results of the operation and postoperative outcomes of the Wongsiri technique with a MiniSURE Kit®.
20 patients underwent carpal tunnel release using the Wongsiri technique and a MiniSURE Kit® with a five-step surgery: MIS starts when the surgeon makes a 1.5-1.8 cm incision, creates a working space, inserts the visual tube of MiniSURE View, inserts the freer, and then cuts the transverse carpal ligament by using the MiniSURE Cut.
All 20 successes of the Wongsiri technique and MiniSURE Kit® surgery occurred within 6.8 minutes operative time and a 12 mm wound size. A single outlier, in one case (6.7%), the patient experienced pillar pain which abated within one month. Patients can return to work in 7.3 days.
The Wongsiri technique with the MiniSURE Kit® demonstrated good outcomes similar to the endoscope. By contrast with the endoscopic surgery, the Wongsiri technique with the MiniSURE Kit® reduced preop, operating, and postop time, many resources, and significant costs and resulted in no nerve problems or complications.
与使用MiniSURE套件(泰国曼谷外科创新医疗保健有限公司)的Wongsiri技术进行的微创手术相比,腕管手术的标准开放技术存在更多的伤口问题和并发症,特别是开放技术手术需要更长的时间才能恢复工作。与常用的开放技术相比,使用内窥镜设备进行腕管减压术(CTR)可减少伤口问题,改善手术效果;然而,内窥镜手术比开放技术更容易出现神经并发症和损伤。Wongsiri技术使用诸如MiniSURE View(用于改善视野和视线)和MiniSURE Cut(通过视网膜上技术进行改进和完整切割,可减少与腕管内窥镜工具相关的神经问题)等新型医疗设备产生了良好的效果。
评估使用MiniSURE套件的Wongsiri技术的手术结果和术后效果。
20例患者采用Wongsiri技术和MiniSURE套件进行腕管松解术,手术分五步进行:微创手术开始时,外科医生做一个1.5 - 1.8厘米的切口,创建工作空间,插入MiniSURE View的可视管,插入剥离子,然后使用MiniSURE Cut切断腕横韧带。
使用Wongsiri技术和MiniSURE套件进行的手术全部成功,手术时间在6.8分钟以内,伤口大小为12毫米。有一例(6.7%)出现异常情况,患者经历了柱痛,一个月内缓解。患者可在7.3天内恢复工作。
使用MiniSURE套件的Wongsiri技术显示出与内窥镜相似的良好效果。与内窥镜手术相比,使用MiniSURE套件的Wongsiri技术减少了术前、手术中和术后时间、许多资源和大量成本,且未出现神经问题或并发症。