Department of Otorhinolaryngology, Yonsei University College of Medicine, Seoul, South Korea.
Laryngoscope. 2020 Dec;130(12):E926-E932. doi: 10.1002/lary.28514. Epub 2020 Jan 24.
OBJECTIVES/HYPOTHESIS: To investigate the efficacy of direct implantation of a Vibrant Soundbridge (VSB) implant in the oval window (OW) without the use of an OW coupler in patients with severe mixed hearing loss.
Retrospective chart review METHODS: A total of 62 patients underwent VSB implantation between July 2016 and December 2018 at Severance Hospital in Seoul, South Korea. Among them, eight patients (nine ears) with moderate-to-severe mixed hearing loss were implanted with a VSB directly in the OW. A floating mass transducer (FMT) was attached to the stapes footplate and covered with tragal cartilage. The outcomes were evaluated using pure-tone audiogram and speech audiogram preoperatively and postoperatively. Word recognition score (WRS; % correct) were measured at the most comfortable loudness (MCL) level to evaluate speech perception.
All cases posed difficulty with round window vibroplasty during surgery, and eventually, an FMT was appropriately placed in the OW without a coupler. Preoperative and postoperative bone conduction thresholds were not different. VSB-aided threshold improved in terms of functional and effective gains. Interestingly, four cases showed improved air conduction thresholds without the use of a VSB. In addition, MCL level with a VSB was significantly lower than that with a hearing aid, and VSB-aided WRS improved over time.
Direct implantation of a VSB in the OW without the use of a coupler showed favorable hearing outcomes, and the OW vibroplasty was safe. Direct OW vibroplasty without a coupler is a reliable procedure and can be a good option for hearing rehabilitation in patients with severe mixed hearing loss.
4 Laryngoscope, 2020.
目的/假说:研究在不使用圆窗耦合器的情况下,将 Vibrant Soundbridge(VSB)植入体直接植入患者严重混合性听力损失的圆窗(OW)中的疗效。
回顾性图表回顾
2016 年 7 月至 2018 年 12 月,韩国首尔 Severance 医院共对 62 例患者进行了 VSB 植入术。其中,8 例(9 耳)中-重度混合性听力损失患者将 VSB 直接植入 OW。浮动质量换能器(FMT)连接在镫骨足板上,并覆盖于耳廓软骨。使用纯音听力图和言语听力图在术前和术后评估结果。使用最舒适响度(MCL)水平的单词识别得分(WRS;%正确)来评估言语感知。
所有病例在手术中进行圆窗振动术时均存在困难,最终未使用耦合器将 FMT 适当放置在 OW 中。术前和术后骨导阈值无差异。VSB 辅助阈值在功能增益和有效增益方面均得到改善。有趣的是,4 例在不使用 VSB 的情况下空气传导阈值得到改善。此外,使用 VSB 的 MCL 水平明显低于使用助听器,并且 VSB 辅助 WRS 随时间推移而提高。
不使用耦合器将 VSB 直接植入 OW 可获得良好的听力结果,OW 振动术是安全的。不使用耦合器的直接 OW 振动术是一种可靠的手术方法,可为严重混合性听力损失患者的听力康复提供良好的选择。