• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

多孔硬膜外导管的分流差异

Differential flow from multihole epidural catheters.

作者信息

Power I, Thorburn J

机构信息

University Department of Anaesthetics, Royal Infirmary, Edinburgh.

出版信息

Anaesthesia. 1988 Oct;43(10):876-8. doi: 10.1111/j.1365-2044.1988.tb05605.x.

DOI:10.1111/j.1365-2044.1988.tb05605.x
PMID:3202300
Abstract

The pressures used in vivo to administer epidural doses of local anaesthetic were recorded for 16- and 18-gauge multihole catheters. Observations were made on 10 patients in labour for each catheter gauge. The pressure range for the 16-gauge catheters was 39.9-266 kPa, with a mean of 167.2 kPa, and for 18-gauge, a range of 53.2-266 kPa, mean, 159 kPa. Similar pressures were then applied in vitro to 10 catheters of each gauge, and the flow of fluid observed from the three holes. For each size of catheter, with increasing pressure, flow appeared at the proximal, then the middle, and finally the distal hole. This emphasises that the effect of epidural doses can vary depending on the pressure of injection, especially if the catheter had been passed partially through the dura.

摘要

记录了使用16号和18号多孔导管在体内给予硬膜外剂量局部麻醉剂时的压力。对每种导管规格,观察了10例分娩期患者。16号导管的压力范围为39.9 - 266kPa,平均为167.2kPa;18号导管的压力范围为53.2 - 266kPa,平均为159kPa。然后对每种规格的10根导管在体外施加类似压力,并观察从三个孔流出的液体。对于每种尺寸的导管,随着压力增加,液体先从近端孔流出,然后是中间孔,最后是远端孔。这强调了硬膜外剂量的效果可能因注射压力而异,尤其是当导管部分穿过硬脊膜时。

相似文献

1
Differential flow from multihole epidural catheters.多孔硬膜外导管的分流差异
Anaesthesia. 1988 Oct;43(10):876-8. doi: 10.1111/j.1365-2044.1988.tb05605.x.
2
Glucose in epidural catheter aspirate.
Anesth Analg. 1993 Mar;76(3):546-8. doi: 10.1213/00000539-199303000-00016.
3
A comparison between open-end (single hole) and closed-end (three lateral holes) epidural catheters. Complications and quality of sensory blockade.
Anaesthesia. 1989 Jul;44(7):578-80. doi: 10.1111/j.1365-2044.1989.tb11446.x.
4
Epidural catheters for obstetrics. Terminal hole or lateral eyes?产科硬膜外导管。端孔还是侧孔?
Reg Anesth. 1994 Nov-Dec;19(6):378-85.
5
Epidural catheter migration during labour: an hypothesis for inadequate analgesia.
Can J Anaesth. 1990 Oct;37(7):789-93. doi: 10.1007/BF03006538.
6
The use of a sound-enabled device to measure pressure during insertion of an epidural catheter in women in labour.使用带声音功能的设备在产妇分娩时测量硬膜外导管插入过程中的压力。
Anaesthesia. 2011 Jul;66(7):568-73. doi: 10.1111/j.1365-2044.2011.06696.x. Epub 2011 May 3.
7
Problems with open-end catheters and epidural infusion.
Anaesthesia. 1990 Feb;45(2):170. doi: 10.1111/j.1365-2044.1990.tb14305.x.
8
Multiport epidural catheters: does the air test work?多端口硬膜外导管:空气测试有效吗?
Anesthesiology. 2000 Jun;92(6):1617-20. doi: 10.1097/00000542-200006000-00018.
9
Do Epidural Catheter Size and Flow Rate Affect Bolus Injection Pressure in Different Programmed Intermittent Epidural Bolus Regimens? An In Vitro Study.硬膜外导管的大小和流速是否会影响不同程控间歇硬膜外推注方案中推注压力?一项体外研究。
Anesth Analg. 2019 Dec;129(6):1587-1594. doi: 10.1213/ANE.0000000000003650.
10
New device for the securement of epidural catheters.
Reg Anesth. 1995 Nov-Dec;20(6):545-6.

引用本文的文献

1
Intermittent epidural bolus versus continuous epidural infusions for labor analgesia: A meta-analysis of randomized controlled trials.硬膜外间断推注与持续输注用于分娩镇痛的效果比较:一项随机对照试验的荟萃分析。
PLoS One. 2020 Jun 12;15(6):e0234353. doi: 10.1371/journal.pone.0234353. eCollection 2020.
2
[Neuraxial labor analgesia: a literature review].[椎管内分娩镇痛:文献综述]
Braz J Anesthesiol. 2019 May-Jun;69(3):291-298. doi: 10.1016/j.bjan.2018.12.001. Epub 2019 Feb 15.
3
Programmed Intermittent Epidural Boluses (PIEB): A Superior Technique for Maitenance of Labor Analgesia.
Turk J Anaesthesiol Reanim. 2017 Apr;45(2):67-69. doi: 10.5152/TJAR.2017.09032. Epub 2017 Apr 1.
4
Advancement of epidural catheter from lumbar to thoracic space in children: Comparison between 18G and 23G catheters.儿童硬膜外导管从腰部推进至胸部的情况:18G和23G导管的比较
J Anaesthesiol Clin Pharmacol. 2012 Jan;28(1):21-7. doi: 10.4103/0970-9185.92429.