• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Recurrent Dislocation After Total Hip Arthroplasty: Controversies and Solutions.

作者信息

Sutter E Grant, Jones Stephen A, Kleeman-Forsthuber Lindsay T, Lachiewicz Paul F, Wellman Samuel S

出版信息

Instr Course Lect. 2019;68:169-186.

PMID:32032055
Abstract

Instability remains one of the most common complications after total hip arthroplasty and a notable cause of patient morbidity as well as patient and surgeon dissatisfaction. Isolated dislocations can often be managed successfully with closed reduction; however, recurrent instability poses a substantial diagnostic and therapeutic challenge. The causes are varied and may be related to patient, surgical, and implant factors. A thorough evaluation is important in determining the cause of instability and effectively managing this difficult problem. Management options include component revision for malposition, modular exchange, or revision to specialized components, such as larger femoral heads, constrained liners, or dual-mobility articulations.

摘要

相似文献

1
Recurrent Dislocation After Total Hip Arthroplasty: Controversies and Solutions.
Instr Course Lect. 2019;68:169-186.
2
Constrained Acetabular Liners.受限髋臼衬垫。
J Arthroplasty. 2018 May;33(5):1331-1336. doi: 10.1016/j.arth.2018.01.026. Epub 2018 Mar 7.
3
Total hip arthroplasty instability in Italy.意大利的全髋关节置换术不稳定性
Int Orthop. 2017 Mar;41(3):635-644. doi: 10.1007/s00264-016-3345-6. Epub 2016 Dec 20.
4
Dual-Mobility Articulations for Patients at High Risk for Dislocation.用于脱位高危患者的双动关节
J Arthroplasty. 2016 Sep;31(9 Suppl):131-5. doi: 10.1016/j.arth.2016.03.021. Epub 2016 Mar 17.
5
Utilizing Dual Mobility Components for First-Time Revision Total Hip Arthroplasty for Instability.初次翻修全髋关节置换术治疗不稳定时采用双动组件。
J Arthroplasty. 2018 Feb;33(2):505-509. doi: 10.1016/j.arth.2017.09.029. Epub 2017 Sep 23.
6
Outcomes of Modular Dual Mobility Acetabular Components in Revision Total Hip Arthroplasty.翻修全髋关节置换术中模块化双动髋臼组件的疗效
J Arthroplasty. 2017 Sep;32(9S):S220-S224. doi: 10.1016/j.arth.2017.03.035. Epub 2017 Mar 23.
7
Long-term results of tripolar constrained total hip arthroplasty in revision hip arthroplasty: a minimum follow-up of ten years.三极限制型全髋关节翻修术的长期疗效:至少十年的随访结果。
Bone Joint J. 2019 Jun;101-B(6_Supple_B):123-126. doi: 10.1302/0301-620X.101B6.BJJ-2018-1484.R1.
8
Dissociation and Intrapelvic Entrapment of a Dual-mobility Polyethylene Component.双动聚乙烯组件的分离与盆腔内卡压
Clin Orthop Relat Res. 2016 Apr;474(4):1072-6. doi: 10.1007/s11999-015-4381-z. Epub 2015 Jun 19.
9
Total hip arthroplasty instability treatment without dual mobility cups: brief overview and experience of other options.不使用双动髋臼杯的全髋关节置换术不稳定治疗:简要概述及其他选择的经验
Int Orthop. 2017 Mar;41(3):661-668. doi: 10.1007/s00264-016-3383-0. Epub 2017 Jan 14.
10
High Failure Rate of Modular Exchange With a Specific Design of a Constrained Liner in High-Risk Patients Undergoing Revision Total Hip Arthroplasty.在接受髋关节翻修置换术的高风险患者中,特定设计的限制性衬垫模块化置换失败率较高。
J Arthroplasty. 2016 Sep;31(9):1963-9. doi: 10.1016/j.arth.2016.02.021. Epub 2016 Feb 17.

引用本文的文献

1
Assessment of Acetabular Component Anteversion after Total Hip Arthroplasty: Comparison of Anteroposterior and Cross-Table Lateral Radiographs with Computed Tomography Scans.全髋关节置换术后髋臼假体前倾角评估:前后位和蛙式位 X 线片与 CT 扫描的比较。
Clin Orthop Surg. 2021 Sep;13(3):329-335. doi: 10.4055/cios20274. Epub 2021 Aug 17.