Center for international Development and Environmental Research (ZEU), Justus Liebig University, Senckenbergstr. 3, 35390 Giessen, Germany.
Institute for Landscape Ecology and Resources Management (ILR), Justus Liebig University, Heinrich-Buff-Ring 26, 35392 Giessen, Germany.
Sensors (Basel). 2020 Feb 6;20(3):859. doi: 10.3390/s20030859.
In situ spectrophotometers measuring in the UV-visible spectrum are increasingly used to collect high-resolution data on stream water quality. This provides the opportunity to investigate short-term solute dynamics, including diurnal cycling. This study reports unusual changes in diurnal patterns observed when such sensors were deployed in four tropical headwater streams in Kenya. The analysis of a 5-year dataset revealed sensor-specific diurnal patterns in nitrate and dissolved organic carbon concentrations and different patterns measured by different sensors when installed at the same site. To verify these patterns, a second mobile sensor was installed at three sites for more than 3 weeks. Agreement between the measurements performed by these sensors was higher for dissolved organic carbon ( > 0.98) than for nitrate ( = 0.43-0.81) at all sites. Higher concentrations and larger amplitudes generally led to higher agreement between patterns measured by the two sensors. However, changing the position or level of shading of the mobile sensor resulted in inconsistent changes in the patterns. The results of this study show that diurnal patterns measured with UV-Vis spectrophotometers should be interpreted with caution. Further work is required to understand how these measurements are influenced by environmental conditions and sensor-specific properties.
原位分光光度计越来越多地用于在紫外-可见光谱范围内采集水质高分辨率数据,从而有机会研究包括昼夜循环在内的短期溶质动态变化。本研究报告了在肯尼亚的四条热带源头溪流中部署这种传感器时观察到的昼夜模式异常变化。对 5 年数据集的分析揭示了硝酸盐和溶解有机碳浓度的传感器特异性昼夜模式,以及在同一地点安装的不同传感器测量的不同模式。为了验证这些模式,第二个移动传感器在三个地点安装了超过 3 周。在所有地点,这些传感器测量的溶解有机碳(> 0.98)之间的一致性高于硝酸盐(= 0.43-0.81)。较高的浓度和较大的幅度通常会导致两个传感器测量的模式之间具有更高的一致性。然而,改变移动传感器的位置或遮光水平会导致模式发生不一致的变化。本研究的结果表明,使用紫外可见分光光度计测量的昼夜模式应谨慎解释。需要进一步的工作来了解这些测量如何受到环境条件和传感器特定性质的影响。