Anal Chem. 2020 Mar 17;92(6):4379-4386. doi: 10.1021/acs.analchem.9b05252. Epub 2020 Feb 25.
Automated in-field methods for measuring dissolved reactive phosphorus (DRP) over a large concentration range are in high demand for the purpose of better understanding the biogeochemistry of phosphorus in the river-estuary-coast continuum to the open ocean. Here, an automated portable and robust analyzer was described for the determination of nanomolar to micromolar levels of DRP in natural waters. The quantification of DRP was based on classic phosphomolybdenum blue (PMB) chemistry. All the components of the analyzer were computer-controlled using LabVIEW-based laboratory-programmed software. When equipped with a 3 cm Z-type flow cell, the system demonstrated linearity with concentrations up to 12 μmol L, a sampling rate of 20 h, a limit of detection of 0.11 μmol L, and relative standard deviations (RSDs) of 0.4-4.6% ( = 11-576). When a solid-phase extraction cartridge was combined with the analyzer, the PMB formed from the sample was automatically concentrated on the hydrophilic-lipophilic balanced sorbent. The concentrated PMB compound was eluted with NaOH solution and measured in the spectrophotometric system. Under optimal conditions, the nanomolar-level mode afforded a sampling rate of 8 h, a limit of detection of 1.7 nmol L, and RSDs of 3.0-5.7% ( = 11-120). The system exhibited advantages that included a wide linear range, high sensitivity and reproducibility, low reagent consumption, and insignificant interference from salinity, silicate, arsenate, and other P-containing compounds. The system was successfully applied for discrete sample analysis, fixed site online monitoring, and the real-time underway measurement of DRP in riverine-estuarine-coastal waters.
自动化现场方法用于测量溶解反应性磷 (DRP) 在很大的浓度范围内是非常需要的,目的是更好地了解磷在河流-河口-海岸连续体到开阔海域的生物地球化学。在这里,描述了一种用于测定自然水中纳摩尔到微摩尔级别的 DRP 的自动化便携式和坚固的分析仪。DRP 的定量是基于经典的磷钼蓝 (PMB) 化学。使用基于 LabVIEW 的实验室编程软件对分析仪的所有组件进行计算机控制。当配备 3 cm Z 型流通池时,该系统在高达 12 μmol L 的浓度范围内表现出线性,采样率为 20 h,检测限为 0.11 μmol L,相对标准偏差 (RSD) 为 0.4-4.6%(= 11-576)。当固相萃取柱与分析仪结合使用时,从样品中形成的 PMB 自动浓缩在亲水-疏水平衡的吸附剂上。浓缩的 PMB 化合物用 NaOH 溶液洗脱并在分光光度系统中测量。在最佳条件下,纳摩尔级模式的采样率为 8 h,检测限为 1.7 nmol L,RSD 为 3.0-5.7%(= 11-120)。该系统具有许多优点,包括宽线性范围、高灵敏度和重现性、低试剂消耗以及盐度、硅酸盐、砷酸盐和其他含磷化合物的干扰可以忽略不计。该系统成功应用于离散样品分析、固定点在线监测以及河流-河口-海岸水域中 DRP 的实时进行测量。