不同手术方案引导下种植手术中种植体位置的二维/三维精度:一项回顾性研究。

2D/3D accuracies of implant position after guided surgery using different surgical protocols: A retrospective study.

机构信息

Department of Biomedical and Neuromotor Sciences, Alma Mater Studiorum - University of Bologna, Bologna, Italy.

Private practice, Battipaglia (SA), Italy.

出版信息

J Prosthodont Res. 2020 Oct;64(4):424-430. doi: 10.1016/j.jpor.2019.11.007. Epub 2020 Feb 13.

Abstract

PURPOSE

To compare the 2D and 3D positional accuracy of four guided surgical protocols using an analysis of linear and angular deviations.

METHODS

DICOM and .STLs files obtained from a CBCT and a digital impression were superimposed with software to plan implant position. Fifty-six patients were subdivided into 4 groups: FGA group (template support [Ts]: teeth [T]; bed preparation [Bp]: fully guided [FG]; implant insertion [Ii]: 3D template [3Dt]; device [D]: manual adapter [MA], FGM group (Ts: T; Bp: FG; Ii: 3Dt; D: fully guided mounter [FGM]), PG group (Ts: T; Bp: FG; Ii: manual; D: none) and MS group (Ts: mucosa; Bp: FG; Ii: 3Dt; D: FGM). The position of 120 implants was assessed by superimposing the planned and final position recorded with a digital impression.

RESULTS

In FGA group, 3D deviations were 0.92 ± 0.52 mm at the implant head and 1.14 ± 0.54 mm at the apex, and the angular deviation (ang. dev.) was 2.45 ± 1.24°. In FGM group, were 0.911 ± 0.44 mm (head) and 1.11 ± 0.54 mm (apex), and the ang. dev. was 2.73 ± 1.96°. In PG group, were 0.95 ± 0.47 mm (head) and 1.17 ± 0.488 mm (apex), and the ang. dev. was 3.71 ± 1.67°. In MS group, were 1.15 ± 0.45 mm (head) and 1.42 ± 0.45 mm (apex), and the ang. dev. was 4.19 ± 2.62°. Ang. dev. of MS group was different from the other groups (P < 0.05).

CONCLUSIONS

Guided surgery showed a sufficient accuracy.

摘要

目的

通过分析线性和角度偏差,比较四种使用引导式手术方案的 2D 和 3D 位置精度。

方法

通过软件将从 CBCT 和数字印模获得的 DICOM 和.STL 文件叠加,以规划种植体位置。将 56 名患者分为 4 组:FGA 组(模板支持 [Ts]:牙齿 [T];备床 [Bp]:全引导 [FG];种植体植入 [Ii]:3D 模板 [3Dt];器械 [D]:手动适配器 [MA])、FGM 组(Ts:T;Bp:FG;Ii:3Dt;D:全引导安装器 [FGM])、PG 组(Ts:T;Bp:FG;Ii:手动;D:无)和 MS 组(Ts:黏膜;Bp:FG;Ii:3Dt;D:FGM)。通过叠加数字印模记录的计划和最终位置来评估 120 个种植体的位置。

结果

在 FGA 组中,种植体头部的 3D 偏差为 0.92 ± 0.52mm,根尖为 1.14 ± 0.54mm,角度偏差(ang. dev.)为 2.45 ± 1.24°。在 FGM 组中,分别为 0.911 ± 0.44mm(头部)和 1.11 ± 0.54mm(根尖),角度偏差为 2.73 ± 1.96°。在 PG 组中,分别为 0.95 ± 0.47mm(头部)和 1.17 ± 0.488mm(根尖),角度偏差为 3.71 ± 1.67°。在 MS 组中,分别为 1.15 ± 0.45mm(头部)和 1.42 ± 0.45mm(根尖),角度偏差为 4.19 ± 2.62°。MS 组的角度偏差与其他组不同(P < 0.05)。

结论

引导式手术具有足够的精度。