To compare the 2D and 3D positional accuracy of four guided surgical protocols using an analysis of linear and angular deviations.
DICOM and .STLs files obtained from a CBCT and a digital impression were superimposed with software to plan implant position. Fifty-six patients were subdivided into 4 groups: FGA group (template support [Ts]: teeth [T]; bed preparation [Bp]: fully guided [FG]; implant insertion [Ii]: 3D template [3Dt]; device [D]: manual adapter [MA], FGM group (Ts: T; Bp: FG; Ii: 3Dt; D: fully guided mounter [FGM]), PG group (Ts: T; Bp: FG; Ii: manual; D: none) and MS group (Ts: mucosa; Bp: FG; Ii: 3Dt; D: FGM). The position of 120 implants was assessed by superimposing the planned and final position recorded with a digital impression.
In FGA group, 3D deviations were 0.92 ± 0.52 mm at the implant head and 1.14 ± 0.54 mm at the apex, and the angular deviation (ang. dev.) was 2.45 ± 1.24°. In FGM group, were 0.911 ± 0.44 mm (head) and 1.11 ± 0.54 mm (apex), and the ang. dev. was 2.73 ± 1.96°. In PG group, were 0.95 ± 0.47 mm (head) and 1.17 ± 0.488 mm (apex), and the ang. dev. was 3.71 ± 1.67°. In MS group, were 1.15 ± 0.45 mm (head) and 1.42 ± 0.45 mm (apex), and the ang. dev. was 4.19 ± 2.62°. Ang. dev. of MS group was different from the other groups (P < 0.05).
Guided surgery showed a sufficient accuracy.
通过分析线性和角度偏差,比较四种使用引导式手术方案的 2D 和 3D 位置精度。
通过软件将从 CBCT 和数字印模获得的 DICOM 和.STL 文件叠加,以规划种植体位置。将 56 名患者分为 4 组:FGA 组(模板支持 [Ts]:牙齿 [T];备床 [Bp]:全引导 [FG];种植体植入 [Ii]:3D 模板 [3Dt];器械 [D]:手动适配器 [MA])、FGM 组(Ts:T;Bp:FG;Ii:3Dt;D:全引导安装器 [FGM])、PG 组(Ts:T;Bp:FG;Ii:手动;D:无)和 MS 组(Ts:黏膜;Bp:FG;Ii:3Dt;D:FGM)。通过叠加数字印模记录的计划和最终位置来评估 120 个种植体的位置。
在 FGA 组中,种植体头部的 3D 偏差为 0.92 ± 0.52mm,根尖为 1.14 ± 0.54mm,角度偏差(ang. dev.)为 2.45 ± 1.24°。在 FGM 组中,分别为 0.911 ± 0.44mm(头部)和 1.11 ± 0.54mm(根尖),角度偏差为 2.73 ± 1.96°。在 PG 组中,分别为 0.95 ± 0.47mm(头部)和 1.17 ± 0.488mm(根尖),角度偏差为 3.71 ± 1.67°。在 MS 组中,分别为 1.15 ± 0.45mm(头部)和 1.42 ± 0.45mm(根尖),角度偏差为 4.19 ± 2.62°。MS 组的角度偏差与其他组不同(P < 0.05)。
引导式手术具有足够的精度。