Department of General Dentistry, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou, China.
J Esthet Restor Dent. 2020 Apr;32(3):265-271. doi: 10.1111/jerd.12573. Epub 2020 Feb 16.
To describe a method to fabricate donor tooth replica to assist surgeons in preparation of recipient socket during tooth autotransplantation.
A total of 28 compromised molars in 27 patients were transplanted with third molars using computer-aided rapid prototyping (CARP) technique. Surgery time and extra-alveolar time were documented. Postoperatively, the distance between cervix of transplanted tooth and the alveolar wall was measured. The degree of postoperative pain experienced was assessed with visual analog scale at day 1, 3, and 7.
From 28 clinical cases, the average extra-alveolar time and surgery time were 2.5 minutes (±1.3) and 44 minutes (±6.8), respectively. Postoperatively, the average distance between cervix of transplanted tooth and the alveolar wall was 0.87 mm (±0.15) at the mesial-cervix, 0.95 mm (±0.17) at the distal-cervix, 0.88 mm (±0.18) at the buccal-cervix, and 0.95 mm (±0.13) at the lingual-cervix. The value of visual analog scale score significantly decreased from day 1 to day 3.
CARP is a reliable technique for fabrication of tooth like surgical replicas in conventional autotransplantation.
CARP technique minimized extra-oral time, reduced iatrogenic damage, and consequently increased the survival rate of tooth autotransplantation.
描述一种制作供体牙复制模型的方法,以协助外科医生在牙自体移植中准备受植体窝。
使用计算机辅助快速成型(CARP)技术,对 27 名患者的 28 颗受损磨牙进行了第三磨牙移植。记录手术时间和牙槽外时间。术后测量移植牙颈缘与牙槽壁之间的距离。术后第 1、3 和 7 天采用视觉模拟评分法评估术后疼痛程度。
28 例临床病例中,平均牙槽外时间和手术时间分别为 2.5 分钟(±1.3)和 44 分钟(±6.8)。术后,移植牙颈缘与牙槽壁之间的平均距离为近中颈缘 0.87mm(±0.15),远中颈缘 0.95mm(±0.17),颊侧颈缘 0.88mm(±0.18),舌侧颈缘 0.95mm(±0.13)。视觉模拟评分从第 1 天到第 3 天显著下降。
CARP 是常规自体移植中制作类似手术的牙复制模型的可靠技术。