Suppr超能文献

原发性和翻修全髋关节置换术中高多孔钛髋臼组件:系统评价。

Highly Porous Titanium Acetabular Components in Primary and Revision Total Hip Arthroplasty: A Systematic Review.

机构信息

The Stavros Niarchos Foundation Complex Joint Reconstruction Center, Hospital for Special Surgery, New York NY.

2(nd) Orthopaedic Department, National and Kapodistrian University of Athens, School of Medicine, Athens, Greece.

出版信息

J Arthroplasty. 2020 Jun;35(6):1737-1749. doi: 10.1016/j.arth.2020.01.052. Epub 2020 Jan 28.

Abstract

BACKGROUND

A number of papers have been published reporting on the clinical performance of highly porous coated titanium acetabular cups in primary and revision total hip arthroplasty (THA). However, no systematic review of the literature has been published to date.

METHODS

The US National Library of Medicine (PubMed/MEDLINE), Embase, and the Cochrane Database of Systematic Reviews were queried for publications utilizing the following keywords: "tritanium" OR "highly-porous" AND "titanium" OR "acetabular" AND "trabecular" AND "titanium".

RESULTS

Overall, 16 studies were included in this review (11,366 cases; 60% females, 2-7 years mean follow-up). The overall survival rate of highly porous titanium acetabular components in primary cases was 99.3% (10,811 of 10,886 cases), whereas the rate of aseptic loosening was 0.1%. The overall survival rate of the highly porous titanium acetabular components in revision THA cases was 93.5% (449 of 480 cases), whereas the rate of aseptic loosening was 2.1%.

CONCLUSION

There was moderate quality evidence to show that the use of highly porous titanium acetabular components in primary and revision THA cases is associated with satisfactory clinical outcomes in the short- and medium-term, without showing any evidence of cup migration or radiolucency. Taking into consideration that there is no evidence yet regarding the long-term survivorship of these components, we feel that further research of higher quality is required to generate more evidence-based conclusions regarding the longevity of highly porous titanium acetabular implants compared with conventional titanium counterparts.

摘要

背景

有许多文献报道了高多孔涂层钛髋臼杯在初次和翻修全髋关节置换术(THA)中的临床性能。然而,迄今为止,尚未发表对文献的系统评价。

方法

美国国家医学图书馆(PubMed/MEDLINE)、Embase 和 Cochrane 系统评价数据库使用以下关键词检索文献:“titanium”或“highly-porous”和“titanium”或“acetabular”和“trabecular”和“titanium”。

结果

共有 16 项研究纳入本综述(11366 例,女性占 60%,平均随访 2-7 年)。初次使用高多孔钛髋臼组件的总体生存率为 99.3%(10811/10886 例),无菌性松动率为 0.1%。翻修 THA 中高多孔钛髋臼组件的总体生存率为 93.5%(449/480 例),无菌性松动率为 2.1%。

结论

有中等质量证据表明,初次和翻修 THA 中使用高多孔钛髋臼组件在短期和中期可获得满意的临床结果,且无杯迁移或射线透亮迹象。考虑到这些组件的长期存活率尚无证据,我们认为需要进一步开展高质量的研究,以获得有关高多孔钛髋臼植入物与传统钛合金植入物相比的长期生存率的更具证据基础的结论。