Lovell D P, Fellows M, Saul J, Whitwell J, Custer L, Dertinger S, Escobar P, Fiedler R, Hemmann U, Kenny J, Smith R, van der Leede B M, Zeller A
St George's Medical School, University of London, Cranmer Terrace, London, SW17 0RE, UK.
Astra Zeneca, Drug Safety and Metabolism, Cambridge, CB4 0WG, UK.
Mutat Res Genet Toxicol Environ Mutagen. 2020 Jan;849:503086. doi: 10.1016/j.mrgentox.2019.503086. Epub 2019 Oct 12.
A database of micronuclei counts for historical negative control data from rat in vivo micronuclei tests performed in 10 different laboratories was established. Data were available from over 4000 negative control rats from 10 laboratories. The mean frequency of micronucleated cells (MN)/1000 cells ranged from 0.44 to 2.22, a 5-fold range. Overall there were no major sex or strain differences in frequency, although there were some small but statistically significant differences within laboratories. There was appreciable variability between experiments compared with variability within experiments in some laboratories. No specific factor was identified which could explain this variability although it was noted that many different vehicles were used in the experiments. It is hoped that these data will help laboratories beginning studies with the rat micronucleus assay and those involved in the assessment of micronucleus assay results.
建立了一个数据库,其中包含在10个不同实验室进行的大鼠体内微核试验的历史阴性对照数据的微核计数。数据来自10个实验室的4000多只阴性对照大鼠。微核化细胞(MN)/1000细胞的平均频率范围为0.44至2.22,相差5倍。总体而言,频率上没有主要的性别或品系差异,尽管在各实验室内存在一些小的但具有统计学意义的差异。与一些实验室的实验内变异性相比,实验间存在明显的变异性。尽管注意到实验中使用了许多不同的赋形剂,但未发现可解释这种变异性的具体因素。希望这些数据将有助于开始进行大鼠微核试验研究的实验室以及参与微核试验结果评估的人员。