Anal Bioanal Chem. 2020 May;412(12):2785-2793. doi: 10.1007/s00216-020-02505-y. Epub 2020 Feb 25.
Epinephrine autoinjectors (EAIs) are important first aid medications for treating anaphylaxis. A 10-fold price increase over the past 12 years and evidence that expired EAIs may still contain significant doses of available epinephrine have motivated interest in the efficacy of expired EAIs as treatments of last resort. Degradation of expired EAIs, which can be caused by improper storage conditions, results in various degrees of discoloration of the epinephrine solution. Previous studies have determined that significant epinephrine remains available in expired EAIs, but these have only considered EAIs that show no discoloration. Here, we investigate the potential for colorimetric estimation of available epinephrine dose based on the degree of discoloration in expired EAIs. The correlation of available epinephrine dose and time since expiration date was poor (r = - 0.37), as determined by an industry standard UHPLC protocol. Visible absorbance of the samples integrated across the range 430-475 nm correlated well with available epinephrine dose (r = - 0.71). This wavelength corresponds to the blue channel of a typical smartphone camera Bayer filter. Smartphone camera images of the EAI solutions in various illumination conditions were analyzed to assign color indices representing the degree of discoloration. Color index of the samples showed similar correlation (|r| > 0.7) with available epinephrine dose as that of visible spectrophotometry. Smartphone imaging colorimetry is proposed as a potential point-of-use epinephrine dose estimator for expired and degraded EAIs. Graphical abstract.
肾上腺素自动注射器 (EAI) 是治疗过敏反应的重要急救药物。在过去 12 年中,其价格上涨了 10 倍,并且有证据表明过期的 EAI 中可能仍含有大量可用的肾上腺素,这激发了人们对过期 EAI 作为最后手段的治疗效果的兴趣。过期的 EAI 会因储存条件不当而降解,导致肾上腺素溶液出现不同程度的变色。以前的研究已经确定过期的 EAI 中仍有大量的肾上腺素可用,但这些研究仅考虑了没有变色的 EAI。在这里,我们研究了根据过期 EAI 变色程度来进行比色法估计可用肾上腺素剂量的可能性。通过行业标准 UHPLC 方案确定,可用肾上腺素剂量与过期日期之间的相关性很差(r = -0.37)。样品的可见吸收率在 430-475nm 范围内积分与可用肾上腺素剂量相关性很好(r = -0.71)。这个波长对应于典型智能手机相机 Bayer 滤波器的蓝色通道。对各种光照条件下 EAI 溶液的智能手机相机图像进行了分析,以分配代表变色程度的颜色指数。与可见分光光度法相比,样品的颜色指数与可用肾上腺素剂量具有相似的相关性(|r| > 0.7)。智能手机成像比色法被提议作为过期和降解 EAI 的潜在即时可用肾上腺素剂量估计器。