Suppr超能文献

数字化全口种植印模与传统全口种植印模:16 例无牙颌上颌的前瞻性研究。

Digital Versus Conventional Full-Arch Implant Impressions: A Prospective Study on 16 Edentulous Maxillae.

机构信息

Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, NY.

Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, MA.

出版信息

J Prosthodont. 2020 Apr;29(4):281-286. doi: 10.1111/jopr.13162. Epub 2020 Mar 24.

Abstract

PURPOSE

A prospective clinical study to compare for the first time the accuracy of digital and conventional maxillary implant impressions for completely edentulous patients.

MATERIALS AND METHODS

Sixteen patients received maxillary implant supported fixed complete dentures. After the verification of the conventional final casts, the casts were scanned with a desktop (extraoral) scanner. Intraoral full-arch digital scans were also obtained with scan bodies and STL files. Extraoral and intraoral scans were superimposed and analyzed with reverse engineering software. The primary outcome measure was the assessment of accuracy between scans of the verified conventional casts and digital full-arch impressions. The secondary outcome was the effect of the implant number on the 3D accuracy of impressions with Spearman's rank correlation coefficient.

RESULTS

The 3D deviations between virtual casts from intraoral full-arch digital scans and digitized final stone casts generated from conventional implant impressions were found to be 162 ± 77 μm. In the 4-implant group, 5-implant group, and 6-implant group the 3D deviations were found to be 139 ± 56 μm, 146 ± 90 μm, and 185 ± 81 μm, respectively. There was a positive correlation between increased implant number and 3D-deviations, but there was no statistically significant difference (p = 0.191).

CONCLUSIONS

The 3D accuracy of full-arch digital implant scans lies within previously reported clinically acceptable threshold. Full-arch digital scans and a complete digital workflow in the fabrication of maxillary fixed complete dentures may be clinically feasible.

摘要

目的

首次前瞻性临床研究比较了数字化和传统上颌种植体印模在完全无牙患者中的准确性。

材料和方法

16 名患者接受了上颌种植体支持的固定全口义齿修复。在验证了传统最终模型后,使用桌面(外口)扫描仪对模型进行扫描。还使用扫描体和 STL 文件获得了全口内数字扫描。使用逆向工程软件对口腔外和口腔内扫描进行叠加和分析。主要结果测量是验证传统模型和数字化全口印模之间扫描准确性的评估。次要结果是使用 Spearman 秩相关系数评估种植体数量对印模三维精度的影响。

结果

从口腔内全口数字扫描的虚拟模型与传统种植体印模数字化最终石模型之间的 3D 偏差为 162±77μm。在 4 个种植体组、5 个种植体组和 6 个种植体组中,3D 偏差分别为 139±56μm、146±90μm 和 185±81μm。种植体数量的增加与 3D 偏差之间存在正相关关系,但无统计学意义差异(p=0.191)。

结论

全口数字化种植扫描的 3D 精度在先前报道的临床可接受范围内。上颌固定全口义齿制作中的全口数字扫描和完整的数字化工作流程可能具有临床可行性。