We evaluated the survivorship, incidence of complications, radiological subsidence, proximal stress shielding, and patient-reported outcomes of a conservative, monoblock, hydroxyapatite-coated femoral stem.
This retrospective cohort study reports on 254 revision hip arthroplasties between January 2006 and June 2016. The mean age of patients was 71 years. The mean length of follow-up was 62 months (range 12-152).
There were 13 stem re-revisions: infection (4), periprosthetic fracture (4), aseptic stem loosening (3), stem fracture (1), and extended trochanteric osteotomy nonunion (1). Kaplan-Meier aseptic stem survivorship was 97.33% (confidence interval 94-100) at 6 years. There were 29 intraoperative fractures. There were 6 cases of subsidence greater than 10 mm; however, none required revision. Ninety-six percent of cases showed no proximal stress shielding. Thigh pain was reported in 3% of cases.
This study confirms that this stem provides good survivorship at 6 years, acceptable complication rates, adequate proximal bone loading, low incidences of thigh pain, and reliable clinical performance in revision hip arthroplasty.
A monoblock, fully hydroxyapatite-coated titanium stem is reliable in revision arthroplasty with mild-moderate femur deficiencies.
我们评估了一种保守的、整体式、羟基磷灰石涂层股骨柄的存活率、并发症发生率、放射学下沉、近端应力遮挡以及患者报告的结果。
本回顾性队列研究报告了 2006 年 1 月至 2016 年 6 月期间的 254 例翻修髋关节置换术。患者的平均年龄为 71 岁。平均随访时间为 62 个月(范围 12-152 个月)。
有 13 例出现翻修:感染(4 例)、假体周围骨折(4 例)、无菌性股骨柄松动(3 例)、股骨柄骨折(1 例)和延长转子间截骨不愈合(1 例)。Kaplan-Meier 无菌股骨柄存活率为 6 年时 97.33%(置信区间 94-100)。术中发生 29 例骨折。有 6 例下沉大于 10 毫米,但均无需翻修。96%的病例无近端应力遮挡。3%的病例出现大腿疼痛。
本研究证实,该股骨柄在 6 年时具有良好的存活率、可接受的并发症发生率、充分的近端骨负荷、大腿疼痛发生率低、在翻修髋关节置换术中具有可靠的临床性能。
整体式、全羟基磷灰石涂层钛股骨柄在股骨轻度至中度缺损的翻修中可靠。