Krause U, Eriksen H L
Department of Ophthalmology, University of Oulu, Finland.
Acta Ophthalmol (Copenh). 1988 Oct;66(5):565-71. doi: 10.1111/j.1755-3768.1988.tb04381.x.
Patients underwent intracapsular cataract extraction and implantation of a Choyce Mk IX anterior chamber intraocular lens. At fluorescein angiography (FAG) at a mean of 8 months post-operatively, 9 showed leaking from the iridal vessels, and 3 were normal: Three cases were excluded because of factors affecting the iris FAG. At a mean of 37 months 5 still had a slight degree of leakage. No primarily negative iris FAG changed to positive later. Fluorescein gonioscopic photography (FGP) revealed leakage in 29.5% of the tips of the foot plates at a mean of 37 months. No correlation was observable between FGP and gonioscopy. The pupillary deformation quotient DQ (greatest: smallest pupillary diameter) was significantly greater at a mean of 8 months in the eyes with leakage in iris FAG than in eyes without leakage (P = 0.0145). Individually a change both in direction against normalisation and in elongation was recorded during the observation time.
患者接受了囊内白内障摘除术,并植入了Choyce Mk IX前房型人工晶状体。术后平均8个月进行荧光素血管造影(FAG)时,9例显示虹膜血管渗漏,3例正常:3例因影响虹膜FAG的因素被排除。平均37个月时,5例仍有轻度渗漏。最初FAG阴性的病例后来没有转为阳性。平均37个月时,荧光素前房角镜摄影(FGP)显示29.5%的脚板尖端有渗漏。FGP与前房角镜检查之间未观察到相关性。平均8个月时,虹膜FAG有渗漏的眼睛的瞳孔变形系数DQ(最大瞳孔直径:最小瞳孔直径)显著大于无渗漏的眼睛(P = 0.0145)。在观察期间,个体记录到了与正常化方向相反的变化以及伸长变化。