Suppr超能文献

overnight/first-morning 尿游离甲氧基肾上腺素和甲氧基酪胺用于嗜铬细胞瘤和副神经节瘤的诊断:这是一种选择吗?

Overnight/first-morning urine free metanephrines and methoxytyramine for diagnosis of pheochromocytoma and paraganglioma: is this an option?

机构信息

Institute of Clinical Chemistry and Laboratory Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.

Department of Medicine III, University Hospital Carl Gustav Carus, Technische Universität Dresden, Dresden, Germany.

出版信息

Eur J Endocrinol. 2020 May;182(5):499-509. doi: 10.1530/EJE-19-1016.

Abstract

OBJECTIVE

Sympathoadrenal activity is decreased during overnight rest. This study assessed whether urinary-free normetanephrine, metanephrine and methoxytyramine in overnight/first-morning urine collections might offer an alternative to measurements in 24-h collections or plasma for diagnosis of pheochromocytoma and paraganglioma (PPGL).

DESIGN AND METHODS

Prospective multicenter cross-sectional diagnostic study involving 706 patients tested for PPGL, in whom tumors were confirmed in 79 and excluded in 627 after follow-up. Another 335 age- and sex-matched volunteers were included for reference purposes. Catecholamines and their free O-methylated metabolites were measured in 24-h collections divided according to waking and sleeping hours and normalized to creatinine. Plasma metabolites from blood sampled after supine rest were measured for comparison.

RESULTS

Urinary outputs of norepinephrine, normetanephrine, epinephrine and metanephrine in the reference population were respectively 50 (48-52)%, 35 (32-37)%, 76 (74-78)% and 15 (12-17)% lower following overnight than daytime collections. Patients in whom PPGLs were excluded showed 28 (26-30)% and 6 (3-9)% day-to-night falls in normetanephrine and metanephrine, while patients with PPGLs showed no significant day-to-night falls in metabolites. Urinary methoxytyramine was consistently unchanged from day to night. According to receiver-operating characteristic curves, diagnostic accuracy of metabolite measurements in overnight/first-morning urine samples did not differ from measurements in 24-h urine collections, but was lower for both than for plasma. Using optimized reference intervals, diagnostic specificity was higher for overnight than daytime collections at similar sensitivities.

CONCLUSIONS

Measurements of urinary-free catecholamine metabolites in first-morning/overnight urine collections offer an alternative for diagnosis of PPGL to 24-h collections but remain less accurate than plasma measurements.

摘要

目的

在夜间休息时,交感肾上腺活性降低。本研究评估了 overnight/first-morning 尿样中的尿游离去甲变肾上腺素、变肾上腺素和甲氧基酪胺测量值是否可以替代 24 小时尿样或血浆测量值用于嗜铬细胞瘤和副神经节瘤(PPGL)的诊断。

设计和方法

这是一项涉及 706 名接受 PPGL 检测的患者的前瞻性多中心横断面诊断研究,其中在随访后 79 例患者被确诊为肿瘤,627 例患者被排除。另外 335 名年龄和性别匹配的志愿者被纳入作为参考。儿茶酚胺及其游离 O-甲基化代谢物按觉醒和睡眠小时数在 24 小时尿液中进行测量,并按肌酐进行标准化。测量卧位休息后采集的血液中的血浆代谢物进行比较。

结果

参考人群中,去甲肾上腺素、变肾上腺素、肾上腺素和变肾上腺素的尿排泄量分别在夜间收集时比白天收集时低 50(48-52)%、35(32-37)%、76(74-78)%和 15(12-17)%。排除 PPGL 的患者的变肾上腺素和变肾上腺素分别出现 28(26-30)%和 6(3-9)%的日夜间下降,而患有 PPGL 的患者的代谢物无明显的日夜间下降。尿甲氧基酪胺从白天到夜间始终保持不变。根据受试者工作特征曲线, overnight/first-morning 尿液样本中代谢物测量的诊断准确性与 24 小时尿液收集没有差异,但低于两者与血浆相比。使用优化的参考区间, overnight 收集的特异性高于白天收集,在相似的敏感性下。

结论

first-morning/overnight 尿样中游离儿茶酚胺代谢物的测量值可替代 24 小时尿样收集用于 PPGL 的诊断,但准确性低于血浆测量值。