Timmer Isabella Regina, Emmink Benjamin Lucas, Leenen Loek Petrus Hendrikus, Govaert Geertje Anna Maria
Department of Trauma Surgery, University Medical Center Utrecht, Utrecht, The Netherlands.
Department of Trauma Surgery, University Medical Center Utrecht, Utrecht, The Netherlands
BMJ Case Rep. 2020 Mar 29;13(3):e233196. doi: 10.1136/bcr-2019-233196.
On the day of scheduled debridement for a persistent pin tract infection, a 23-year old man presented himself carrying a small bony ring sequestrum that had spontaneously ejected from his tibial wound 1 week earlier. Eight years prior to presentation, he was treated for an open crural fracture which was stabilised with an external fixator. Revision of the operation notes revealed that the placement of this external fixator was performed without predrilling.