Suppr超能文献

采用多种类似试剂衍生化进行样品多重化,提高 LC/ESI-MS/MS 测定甾体激素的通量:以血浆 17α-羟孕酮为例。

Sample-multiplexing by derivatization using multiple analogous reagents for enhancing throughput in LC/ESI-MS/MS assay of steroids: Plasma 17α-hydroxyprogesterone as an example.

机构信息

Faculty of Pharmaceutical Sciences, Tokyo University of Science, 2641 Yamazaki, Noda-shi, Chiba 278-8510, Japan.

Toyohashi Municipal Hospital, 50 Hachiken Nishi, Aotake-Cho, Toyohashi-shi, Aichi 441-8570, Japan.

出版信息

J Chromatogr B Analyt Technol Biomed Life Sci. 2020 Jun 1;1146:122117. doi: 10.1016/j.jchromb.2020.122117. Epub 2020 Apr 15.

Abstract

The measurements of steroids in biological fluids are of importance for the diagnosis and treatment of many diseases. Liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) has a high specificity and accuracy for the steroid analysis, whereas it has a lower analysis throughput, which could become a big issue in clinical practice. One of the promising solutions to this issue is the multiplexing of samples in the same injection. In this study, the utility of the sample-multiplexing by the derivatization using multiple analogous reagents was evaluated for enhancing the throughput of the LC/ESI-MS/MS assays of steroids. The plasma 17α-hydroxyprogesterone (17OHP), which is a diagnostic marker for the 21-hydroxylase deficiency, was chosen as the model analyte. The four plasma samples (20 μL each) were separately derivatized with one of four different analogous Girard-type reagents, combined, then injected together into the LC/ESI-MS/MS. By this method, four plasma samples could be analyzed within a single LC run. The developed method could significantly reduce the total LC run time (about 2/5 for 32 samples, compared with the conventional method) with a satisfactory sensitivity (lower limit of quantification 0.5 ng/mL), precision (intra- and inter-assay RSDs ≤ 4.0% and ≤ 3.5%, respectively) and accuracy (97.6-106.7%), and negligible matrix effect. The developed method had a satisfactory applicability for the quantification of 17OHP in the cord plasma samples.

摘要

生物体液中类固醇的测量对于许多疾病的诊断和治疗都很重要。液相色谱/电喷雾电离串联质谱(LC/ESI-MS/MS)在类固醇分析中具有高特异性和准确性,但其分析通量较低,这在临床实践中可能成为一个大问题。解决这个问题的一种有前途的方法是在同一次注射中对样品进行多重化。在这项研究中,通过使用多种类似试剂进行衍生化来实现样品多重化,以提高 LC/ESI-MS/MS 测定类固醇的通量。将作为诊断标志物的血浆 17α-羟孕酮(17OHP)选为模型分析物。四个血浆样品(每个 20 μL)分别用四种不同的类似 Girard 型试剂衍生化,然后混合在一起注入 LC/ESI-MS/MS。通过这种方法,可以在单个 LC 运行中分析四个血浆样品。与传统方法相比,该方法可显著缩短总 LC 运行时间(32 个样品的总 LC 运行时间约缩短 2/5),同时保持满意的灵敏度(定量下限为 0.5ng/mL)、精密度(日内和日间 RSD 分别为≤4.0%和≤3.5%)和准确度(97.6-106.7%),并且基质效应可忽略不计。所开发的方法在对脐血血浆样品中 17OHP 的定量分析中具有良好的适用性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验