Houglum J E, Larson R D, Neal R M
South Dakota State University, Chemistry Department, Brookings.
J Assoc Off Anal Chem. 1988 Sep-Oct;71(5):1054-6.
A reverse-phase liquid chromatographic method for the assay of sulfamethazine (SMZ) in feeds is described. Feed samples are extracted with 50% methanol solution, centrifuged, filtered, and diluted when necessary, and chromatographed on a C-18 column. Samples are eluted with a mobile phase of 20% methanol and 80% of a solution containing acetic acid and tetramethylammonium chloride. The average recovery from spiked samples was 97.2% with a coefficient of variation of 1.2%. Linearity was very good (correlation coefficient 0.9997). Within-day and between-day coefficients of variation averaged 1.3 and 2.6%, respectively. The results for samples assayed by this method compared closely with the results from the same extracts assayed by the AOAC colorimetric method.