Suppr超能文献

[两种甲状腺影像报告和数据系统对甲状腺良恶性结节鉴别诊断的准确性]

[Accuracy of two thyroid imaging, reporting and data systems for differential diagnosis of benign and malignant thyroid nodules].

作者信息

Lai Shuiqing, Chen Yuancheng, Chen Zhijiang, Wang Long, Cong Shuzhen, Kuang Jian

机构信息

Department of Endocrinology, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, China.

Department of Ultrasound, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, China.

出版信息

Nan Fang Yi Ke Da Xue Xue Bao. 2020 Mar 30;40(3):400-406. doi: 10.12122/j.issn.1673-4254.2020.03.19.

Abstract

OBJECTIVE

To compare the accuracy of two widely used thyroid imaging, reporting and data systems (TI-RADS), namely ACR TI-RADS and Kwak TI-RADS, in the differential diagnosis of benign and malignant thyroid nodules.

METHODS

We reviewed the data of 350 thyroid nodules with definite diagnoses by surgical histopathology (=144, 41.14%) or fine needle aspiration (FNA) cytopathology (=206, 58.86%). The nodules were graded using ACR TI-RADS and Kwak TI-RADS based on the ultrasound images, and the diagnostic accuracy of these two systems was evaluated by the area under the receiveroperating characteristic curve (AUC).

RESULTS

The AUCs of ACR TI-RADS and Kwak TI-RADS were both 0.879. For a differential diagnosis of the thyroid nodules, ACR TI-RADS had a diagnostic sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, Youden's index and accuracy of 77.3%, 89.1%, 83.0%, 85.1%, 7.101, 0.255, 27.848, 0.664 and 0.843, respectively, with an optimal threshold of TR5, as compared with 84.8%, 84.0%, 78.3%, 89.0%, 5.283, 0.181, 29.265, 0.688 and 0.843, respectively, of Kwak TI-RADS, which had an optimal threshold of 4c.

CONCLUSIONS

Both ACR TI-RADS and Kwak TI-RADS have good performance for differential diagnosis of thyroid nodules, but ACR TI-RADS has a higher specificity and a lower sensitivity compared with Kwak TI-RADS.

摘要

目的

比较两种广泛应用的甲状腺影像报告和数据系统(TI-RADS),即美国放射学会(ACR)TI-RADS和夸克(Kwak)TI-RADS在鉴别甲状腺良恶性结节中的准确性。

方法

我们回顾了350个经手术组织病理学(=144个,41.14%)或细针穿刺(FNA)细胞病理学(=206个,58.86%)明确诊断的甲状腺结节的数据。根据超声图像,使用ACR TI-RADS和Kwak TI-RADS对结节进行分级,并通过受试者操作特征曲线(AUC)下面积评估这两种系统的诊断准确性。

结果

ACR TI-RADS和Kwak TI-RADS的AUC均为0.879。对于甲状腺结节的鉴别诊断,ACR TI-RADS的诊断敏感性、特异性、阳性预测值、阴性预测值、阳性似然比、阴性似然比、诊断比值比、约登指数和准确性分别为77.3%、89.1%、83.0%、85.1%、7.101、0.255、27.848、0.664和0.843,最佳阈值为TR5;相比之下,Kwak TI-RADS的上述指标分别为84.8%、84.0%、78.3%、89.0%、5.283、0.181、29.265、0.688和0.843,最佳阈值为4c。

结论

ACR TI-RADS和Kwak TI-RADS在鉴别甲状腺结节方面均有良好表现,但与Kwak TI-RADS相比,ACR TI-RADS具有更高的特异性和更低的敏感性。

相似文献

本文引用的文献

3
Thyroid nodules in children and adolescents.儿童和青少年甲状腺结节。
Curr Opin Endocrinol Diabetes Obes. 2019 Oct;26(5):266-274. doi: 10.1097/MED.0000000000000495.
9
The changing incidence of thyroid cancer.甲状腺癌发病率的变化
Nat Rev Endocrinol. 2016 Nov;12(11):646-653. doi: 10.1038/nrendo.2016.110. Epub 2016 Jul 15.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验