Department of Ophthalmology, Shanghai Ninth Peoples Hospital Affiliated to Shanghai JiaoTong University School of Medicine , Shanghai, China.
Ophthalmology, Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology , Shanghai, China.
Curr Eye Res. 2020 Nov;45(11):1453-1457. doi: 10.1080/02713683.2020.1752388. Epub 2020 May 12.
: To evaluate the optical quality of highly myopic eyes under light and dark conditions and correlate it with other relevant parameters. : A cross-sectional, observational study was performed on 180 eyes of 90 highly myopic patients (29 males and 61 females; mean age: 27.833 ± 0.364 years [range: 18-45 years]). The modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and predicted visual acuity (PVA; 100%, 20%, and 9%) under different lighting conditions were measured to evaluate the optical quality, which was correlated with probable relevant factors, including, axis length, spherical equivalent (SE), uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BDVA), astigmatism, and corneal curvature. The relationship between these visual parameters and optical quality was analyzed using a generalized linear model. : The OSIs were 1.241 ± 0.068 and 1.515 ± 0.076; the MTF cutoff frequencies were 37.725 ± 0.559 and 30.238 ± 0.550 cpd; the Strehl ratios were 0.219 ± 0.004 and 0.175 ± 0.003; and the PVAs at 100%, 20%, and 9% were 1.257 ± 0.019 and 1.001 ± 0.018, 0.949 ± 0.017 and 0.719 ± 0.015, and 0.579 ± 0.011 and 0.439 ± 0.010, under bright and dark conditions respectively. The optical quality parameters were correlated with age, SE, BDVA, corneal astigmatism, and curvature to different degrees under different lighting conditions. : The optical quality declined in highly myopic eyes under both bright and dark lighting conditions. SE, BDVA, corneal astigmatism, and curvature were correlated with optical quality to different degrees under different lighting conditions.
评估不同光照条件下高度近视眼的光质量,并将其与其他相关参数相关联。
这是一项横断面观察性研究,共纳入 90 例(29 名男性和 61 名女性)180 只高度近视眼患者。测量调制传递函数(MTF)截止频率、斯特列尔比、客观散射指数(OSI)和不同照明条件下的预测视力(100%、20%和 9%),以评估光学质量,并将其与可能的相关因素相关联,包括眼轴长度、等效球镜(SE)、未矫正远视力(UDVA)、最佳矫正远视力(BDVA)、散光和角膜曲率。使用广义线性模型分析这些视觉参数与光学质量之间的关系。
OSI 分别为 1.241±0.068 和 1.515±0.076;MTF 截止频率分别为 37.725±0.559 和 30.238±0.550 cpd;Strehl 比分别为 0.219±0.004 和 0.175±0.003;100%、20%和 9%的 PVA 分别为 1.257±0.019 和 1.001±0.018、0.949±0.017 和 0.719±0.015、0.579±0.011 和 0.439±0.010,分别在明亮和黑暗条件下。在不同的照明条件下,光学质量参数与年龄、SE、BDVA、角膜散光和曲率之间存在不同程度的相关性。
高度近视眼在明亮和黑暗照明条件下的光质量均下降。SE、BDVA、角膜散光和曲率在不同的照明条件下与光质量有不同程度的相关性。