Suppr超能文献

囊袋张力环植入对假性剥脱综合征患者白内障手术后预测屈光不正的影响。

Effect of capsular tension ring implantation on predicted refractive error after cataract surgery in patients with pseudoexfoliation syndrome.

作者信息

Malekahmadi Mohammad, Kazemi Sadegh, Sharifipour Farideh, Ostadian Farshad, Mahdian Rad Atefeh, Mirdehghan Mohammad Sadegh

机构信息

Department of Ophthalmology, Infectious Ophthalmologic Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz 6193673111, Iran.

出版信息

Int J Ophthalmol. 2020 Apr 18;13(4):587-590. doi: 10.18240/ijo.2020.04.09. eCollection 2020.

Abstract

AIM

To investigate the effect of capsular tension ring (CTR) implantation on predicted refractive error after cataract surgery in patients with pseudoexfoliation (PEX) syndrome.

METHODS

This double-blind randomized clinical trial was conducted on 60 patients with PEX syndrome referring to Imam Khomeini Hospital affiliated to Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran, for undergoing cataract surgery. The study population was divided into two groups, namely CTR group (=30) and non-CTR group (control group; =30). The refractive error and anterior chamber depth (ACD) were measured 1wk, 1mo, and 3mo after phacoemulsification (PE) surgery.

RESULTS

The results indicated no statistically significant difference between the two groups in terms of predicted refractive error (obtained by subtracting preoperative predicted refractive error from actual postoperative refractive error) 1wk (=0.47), 1mo (0.30), and 3mo (=0.06) after the PE surgery. Regarding the CTR group, the changes of ACD was statistically significant 1 and 3mo after the PE surgery, compared to those obtained 1wk post-surgery (=0.005).

CONCLUSION

The CTR implantation in PEX cataractous patients without zonulysis has no statistically significant effect on the predicted refraction and ACD changes after PE. The predicted refraction error has a hyperopic shift in both groups. The results reveal the unnecessary of calculating modified IOL in CTR implantation.

摘要

目的

探讨囊袋张力环(CTR)植入对假性剥脱(PEX)综合征患者白内障手术后预测屈光不正的影响。

方法

本双盲随机临床试验对60例因白内障手术转诊至伊朗阿瓦士阿瓦士贾undishapur医科大学附属伊玛目霍梅尼医院的PEX综合征患者进行。研究人群分为两组,即CTR组(=30)和非CTR组(对照组;=30)。在超声乳化(PE)手术后1周、1个月和3个月测量屈光不正和前房深度(ACD)。

结果

结果表明,在PE手术后1周(=0.47)、1个月(0.30)和3个月(=0.06),两组在预测屈光不正(通过用术后实际屈光不正减去术前预测屈光不正获得)方面无统计学显著差异。关于CTR组,与PE手术后1周获得的结果相比,PE手术后1个月和3个月ACD的变化具有统计学显著性(=0.005)。

结论

在无晶状体悬韧带溶解的PEX白内障患者中植入CTR对PE术后预测屈光和ACD变化无统计学显著影响。两组的预测屈光不正均有远视性偏移。结果表明在CTR植入中计算改良人工晶状体是不必要的。

相似文献

本文引用的文献

8
Effect of a capsular tension ring on axial intraocular lens position.囊袋张力环对人工晶状体轴向位置的影响。
J Cataract Refract Surg. 2015 Jan;41(1):122-5. doi: 10.1016/j.jcrs.2014.04.035. Epub 2014 Nov 20.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验