真性剥脱性眼病白内障超声乳化术后前房深度的变化及其对人工晶状体屈光力计算准确性的影响。

Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation.

作者信息

Gür Güngör Sirel, Akman Ahmet, Asena Leyla, Aksoy Mustafa, Sarıgül Sezenöz Almila

机构信息

Başkent University Faculty of Medicine, Department of Ophthalmology, Ankara, Turkey.

出版信息

Turk J Ophthalmol. 2016 Dec;46(6):255-258. doi: 10.4274/tjo.56659. Epub 2016 Dec 1.

Abstract

OBJECTIVES

To compare anterior chamber depth (ACD) changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX) and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intraocular lens (IOL) power calculation and postoperative refraction.

MATERIALS AND METHODS

Twenty-two eyes of 22 patients with PEX and 30 eyes of 30 normal patients who underwent uneventful phacoemulsification surgery and IOL implantation were included in the study. The ACD of all patients was evaluated preoperatively and at 3 months postoperatively with the ALLEGRO Oculyzer (WaveLight® Oculyzer™ II, Alcon, Novartis)-Scheimpflug imaging system.

RESULTS

The postoperative mean ACD values were significantly larger than the preoperative ACD values in both groups (p<0.001 for both groups). The pre- to postoperative change in ACD was 0.46±0.3 mm in the PEX group, which was a larger change than seen in the normal patients (0.12±0.1 mm) (p=0.04). The mean absolute errors (MAE) calculated with different IOL formulas (SRK/T, Haigis, Hoffer and Holladay 1 formulas) were comparable and no statistically significant difference was observed between the two groups (p=0.21).

CONCLUSION

Phacoemulsification induces more significant ACD changes in patients with PEX compared to normal patients. However, the MAE did not differ significantly between the groups.

摘要

目的

采用眼前节成像方法比较真性剥脱综合征(PEX)患者和正常患者白内障超声乳化吸除术后前房深度(ACD)的变化。本研究的另一个目的是评估这些变化对人工晶状体(IOL)屈光力计算准确性和术后屈光状态的影响。

材料与方法

本研究纳入了22例接受了顺利的白内障超声乳化吸除术和IOL植入术的PEX患者的22只眼,以及30例正常患者的30只眼。所有患者术前及术后3个月均使用ALLEGRO眼前节分析仪(WaveLight® Oculyzer™ II,爱尔康,诺华)-Scheimpflug成像系统评估ACD。

结果

两组患者术后平均ACD值均显著大于术前ACD值(两组均p<0.001)。PEX组ACD术前至术后的变化为0.46±0.3mm,大于正常患者(0.12±0.1mm)(p=0.04)。使用不同IOL公式(SRK/T、Haigis、Hoffer和Holladay 1公式)计算的平均绝对误差(MAE)具有可比性,两组间未观察到统计学显著差异(p=0.21)。

结论

与正常患者相比,白内障超声乳化吸除术在PEX患者中引起的ACD变化更显著。然而,两组间MAE无显著差异。