Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, Republic of Korea.
BALGEUN-EYE21 Operation Center, Gwangju, 61932, Republic of Korea.
BMC Ophthalmol. 2020 May 14;20(1):192. doi: 10.1186/s12886-020-01459-0.
To compare the outcomes of myopia and myopic astigmatism corrected with topography-modified refraction laser in situ keratomileusis (TMR-LASIK), wavefront-optimized (WFO) LASIK, and topography-guided (TG) LASIK with a correction target based on the manifest refraction (manifest TG-LASIK).
This observational, retrospective cohort study included patients who underwent LASIK using the WaveLight® EX500 excimer laser to correct myopia and myopic astigmatism between August 2016 and July 2017. Patients who underwent TMR-LASIK (85 patients), WFO-LASIK (70 patients), or manifest TG-LASIK (40 patients) were enrolled, and only one eye from each patient was analyzed. All participants underwent measurement of the uncorrected distance visual acuity (UDVA), best-corrected distance visual acuity (BCVA), manifest refraction, vector analysis of astigmatic change, corneal topography, and corneal wavefront analysis at baseline and at every posttreatment visit.
Three months postoperatively, a UDVA of 0.0 logMAR or better and manifest refraction spherical equivalent (MRSE) within ±0.5 diopters (D) did not differ across the TMR-, WFO-, and manifest TG-LASIK groups. However, the residual cylinder in the TMR group was significantly larger than that in the WFO and manifest TG groups. The magnitude of error in the TMR group measured using astigmatism vector analysis was significantly higher than that in the WFO and manifest TG groups.
Although these three LASIK platforms achieved the predicted surgical outcomes, TMR-LASIK overcorrected astigmatism and showed a higher residual postoperative astigmatism compared with WFO- and manifest TG-LASIK.
比较基于角膜地形图引导的基于客观(manifest TG)的准分子激光原位角膜磨镶术(LASIK)、波前像差优化(WFO)LASIK 和基于角膜地形图的光区引导(TG)LASIK 矫正近视和近视散光的结果与经角膜地形图修正的屈光激光原位角膜磨镶术(TMR-LASIK)。
本观察性回顾性队列研究纳入了 2016 年 8 月至 2017 年 7 月期间使用 WaveLight® EX500 准分子激光行 LASIK 矫正近视和近视散光的患者。招募了 TMR-LASIK(85 例患者)、WFO-LASIK(70 例患者)或 manifest TG-LASIK(40 例患者)的患者,且每例患者仅纳入一眼。所有患者均进行未矫正距离视力(UDVA)、最佳矫正距离视力(BCVA)、客观屈光度、散光矢量分析、角膜地形图和角膜波前分析检查。
术后 3 个月,TMR、WFO 和 manifest TG-LASIK 组患者的 UDVA 为 0.0 对数视力(logMAR)或更好,屈光度球镜等效值(MRSE)为±0.5 屈光度(D),各组间无差异。然而,TMR 组的残余散光柱镜度显著大于 WFO 和 manifest TG 组。TMR 组的散光矢量分析的误差幅度显著高于 WFO 和 manifest TG 组。
尽管这三种 LASIK 平台均实现了预测的手术效果,但 TMR-LASIK 矫正近视散光的程度大于 WFO-LASIK 和 manifest TG-LASIK,并且术后残余散光更高。