An automatic on-line high-performance liquid chromatographic method based on a precolumn derivatization with o-phthalaldehyde has been developed to quantitate levels of free amino acids in cerebrospinal fluid (CSF) and plasma samples from 12 patients with multiple sclerosis (MS) and 12 controls. The analytical method gave reproducible results with relative standard deviations of 0.5-3% for all amino acids. The separation of 24 amino acids was performed on a reversed-phase C18 column, using two solvents and a multiple-step gradient. Each chromatographic experiment was completed within 40 min. The results showed higher levels of Glu, Gln, Gly and Ala and lower levels of Met, Val, Phe and Lys in plasma of MS patients. In CSF, increased levels of Gln, Arg, Ser and Tyr and decreased levels of Asp, Glu, Met, gamma-aminobutyric acid and Phe were found in MS patients, whereas the levels of other amino acids remained more or the less same in both groups.

摘要

已开发出一种基于邻苯二甲醛柱前衍生化的自动在线高效液相色谱法,用于定量检测12例多发性硬化症(MS)患者和12例对照者脑脊液(CSF)和血浆样本中的游离氨基酸水平。该分析方法对所有氨基酸的重现性良好,相对标准偏差为0.5%-3%。使用两种溶剂和多步梯度,在反相C18柱上对24种氨基酸进行分离。每次色谱实验在40分钟内完成。结果显示,MS患者血浆中Glu、Gln、Gly和Ala水平较高,而Met、Val、Phe和Lys水平较低。在脑脊液中,MS患者Gln、Arg、Ser和Tyr水平升高,Asp、Glu、Met、γ-氨基丁酸和Phe水平降低,而两组中其他氨基酸水平或多或少保持相同。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验