Haughey D B, Elmquist W F, Breutzmann D A, Hemphill D G, Constantini E G
Department of Pharmacy Practice, College of Pharmacy, University of Minnesota, Minneapolis 55455.
Pharm Res. 1988 Jan;5(1):10-5. doi: 10.1023/a:1015872309411.
A high-performance liquid chromatographic (HPLC) assay was developed for the determination of di(2-ethylhexyl) phthalate (DEHP) in serum or plasma. Plasma DEHP concentrations that were measured by HPLC in specimens obtained from hemodialysis patients were in good agreement with corresponding concentrations that were measured by gas chromatography with selected ion monitoring (GC-SIM) (r2 = 0.996). Plasma DEHP concentrations were measured after intravenous DEHP administration (1.2-4.4 mg DEHP/kg body weight) to determine the effect of bilateral ureteral ligation on DEHP elimination in the mongrel dog. DEHP plasma clearance (approximately 6.3 ml/min/kg), steady-state distribution volume (approximately 0.21/kg), and terminal half-life (approximately 50 min) were unchanged in two dogs following bilateral ureteral ligation. DEHP terminal half-life and steady-state distribution volume were substantially smaller (25- to 70-fold) than reported previously in the rat or dog.
建立了一种高效液相色谱(HPLC)法,用于测定血清或血浆中的邻苯二甲酸二(2-乙基己基)酯(DEHP)。通过HPLC测定的血液透析患者标本中的血浆DEHP浓度,与通过选择离子监测气相色谱法(GC-SIM)测定的相应浓度高度一致(r2 = 0.996)。在对杂种犬静脉注射DEHP(1.2 - 4.4 mg DEHP/千克体重)后,测定血浆DEHP浓度,以确定双侧输尿管结扎对DEHP在杂种犬体内消除的影响。在两只犬双侧输尿管结扎后,DEHP的血浆清除率(约6.3 ml/分钟/千克)、稳态分布容积(约0.21/千克)和终末半衰期(约50分钟)均未改变。DEHP的终末半衰期和稳态分布容积比先前在大鼠或犬中报道的要小得多(25至70倍)。