Implant Fellow, Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, N.Y.
Assistant Professor, Department of Prosthodontics, Eastman Institute for Oral Health, University of Rochester, Rochester, N.Y.
J Prosthet Dent. 2021 Apr;125(4):585-587. doi: 10.1016/j.prosdent.2020.03.024. Epub 2020 May 23.
A clinical and laboratory workflow for fabricating and retrofitting a monolithic ceramic crown to an existing removable partial denture (RPD) is described. A conventional polyvinyl siloxane impression was made of the prepared tooth with the RPD in place. A stone cast was poured and, after die sectioning, scanned with a tabletop scanner. The ceramic crown was designed and fabricated by using a digital workflow to fit the RPD clasp assembly, providing an adequate undercut for the clasp. The crown was then delivered and the RPD evaluated for adequate fit.
介绍了一种制作和改装整体陶瓷冠到现有可摘局部义齿(RPD)的临床和实验室工作流程。通过在 RPD 就位的情况下对准备好的牙齿进行常规聚硅氧烷印模。浇铸石模型,然后在切片后用台式扫描仪进行扫描。通过数字工作流程设计和制作陶瓷冠,以适应 RPD 卡环组件,为卡环提供足够的固位形。然后交付冠并评估 RPD 的适配性。