HRT 评估回顾:心率震荡方法学的系统评价。

HRT assessment reviewed: a systematic review of heart rate turbulence methodology.

机构信息

THM University of Applied Sciences, Giessen, Germany.

Vestre Viken Hospital Trust, Kongsberg, Norway.

出版信息

Physiol Meas. 2020 Sep 11;41(8):08TR01. doi: 10.1088/1361-6579/ab98b3.

Abstract

UNLABELLED

Heart rate turbulence (HRT) is a biphasic reaction to a ventricular premature contraction (VPC) mainly mediated by the baroreflex. It can be used for risk stratification in different disease patterns. Despite existing standards there is a lot of variation in terms of measuring and calculating HRT, which complicates research and application.

OBJECTIVE

This systematic review outlines and evaluates the methodological spectrum of HRT research, especially filtering criteria, parameter calculation and thresholds.

APPROACH

The analysis includes all research papers written in English that have been published before 12.10.2018, are listed on PubMed and involve calculation of HRT parameter values.

MAIN RESULTS

HRT assessment is still being performed in various ways and important specifications of the methodology are not given in many articles. Nevertheless, some suggestions regarding HRT methodology can be made: a normalised turbulence slope should be used to uncouple the parameter from heart rate and frequency of extrasystoles. Filtering criteria as formerly reviewed in the guidelines should be met and mentioned. The minimal number of VPC snippets (VPCSs) as well as new cut-off values for different risks need to be further evaluated. Most importantly, the exact and complete methodology must be described to ensure reproducibility and comparability.

SIGNIFICANCE

Methodical variation hinders comparability of research and medical application. Our continuing questions help to further standardise the measurement and calculation of HRT and increase its value for medical risk stratification.

摘要

目的:本系统综述概述并评估了心率震荡(HRT)研究的方法学范围,特别是滤波标准、参数计算和阈值。

方法:分析包括截至 2018 年 12 月 12 日之前发表的所有英文研究论文,这些论文都列在 PubMed 上,且涉及 HRT 参数值的计算。

结果:HRT 评估仍在以各种方式进行,许多文章并未给出该方法的重要规范。然而,可以对 HRT 方法学提出一些建议:应该使用标准化的震荡斜率将参数与心率和早搏频率解耦。应满足并提及以前在指南中审查过的滤波标准。需要进一步评估最小数量的室性早搏片段(VPCs)以及不同风险的新截止值。最重要的是,必须详细描述确切和完整的方法,以确保可重复性和可比性。

意义:方法学的差异阻碍了研究和医学应用的可比性。我们不断提出的问题有助于进一步规范 HRT 的测量和计算,提高其在医学风险分层中的价值。