Kovaļčuka Līga, Mūrniece Gundega
Clinical Institute, Faculty of Veterinary Medicine, Latvia University of Life Science and Technologies, Jelgava, Latvia.
Vet World. 2019 Apr;13(4):807-811. doi: 10.14202/vetworld.2020.807-811. Epub 2020 Apr 28.
The Latvian Hunting dog is the only national dog breed in Latvia and so far, there are no data on the important ophthalmological data pertaining to clinical tests and ocular biometry. The aim of this study was to improve the ocular examination and to document normal reference ranges of the globe axial length (AXL), anterior chamber depth (ACD), lens thickness (LT), intraocular pressure (IOP), and Schirmer tear test (STT).
Sixteen Latvian Hunting dogs (32 eyes) of varying age and sex were included in this study. All dogs underwent an ophthalmic examination followed by tear production (STT) and IOP (TonoVet) measurements. Biometric examination using A-mode ultrasonography was done under topical corneal anesthesia using 0.5% proparacaine hydrochloride. The eyes were scanned using A-mode ultrasonography with a 10 MHz transducer by transcorneal approach. The reference values of IOP, STT, AXL, ACD, and LT are expressed as mean ± standard deviation (SD).
Statistical analysis using the SPSS v.23 and Microsoft Excel 2013 showed no statistically significant differences between the right and left eyes for either of the tests. The mean±SD value of STT and IOP values was 20.9±3.2 mm/min and 17.7±3.2 mmHg, respectively. The mean±SD of the AXL, ACD, and LT obtained by A-mode ultrasound was 2.21±0.1 cm, 0.35±0.1cm, and 0.42±0.06cm, respectively.
This study documents the normal reference ranges of important ophthalmological clinical tests (IOP and STT) and ocular biometry (AXL, ACD, and LT) in Latvian Hunting dogs.
拉脱维亚猎犬是拉脱维亚唯一的本土犬种,迄今为止,尚无关于临床检查和眼部生物测量的重要眼科数据。本研究的目的是改进眼部检查,并记录眼球轴长(AXL)、前房深度(ACD)、晶状体厚度(LT)、眼压(IOP)和泪液分泌试验(STT)的正常参考范围。
本研究纳入了16只不同年龄和性别的拉脱维亚猎犬(32只眼)。所有犬只均接受眼科检查,随后进行泪液分泌(STT)和眼压(TonoVet)测量。在使用0.5%盐酸丙美卡因进行表面角膜麻醉的情况下,采用A超进行生物测量检查。使用10MHz探头通过经角膜途径对眼睛进行A超扫描。IOP、STT、AXL、ACD和LT的参考值以平均值±标准差(SD)表示。
使用SPSS v.23和Microsoft Excel 2013进行的统计分析表明,任何一项测试的左右眼之间均无统计学显著差异。STT和IOP值的平均值±标准差分别为20.9±3.2mm/分钟和17.7±3.2mmHg。通过A超获得的AXL、ACD和LT的平均值±标准差分别为2.21±0.1cm、0.35±0.1cm和0.42±0.06cm。
本研究记录了拉脱维亚猎犬重要眼科临床检查(IOP和STT)和眼部生物测量(AXL、ACD和LT)的正常参考范围。