Suppr超能文献

评估糖化血红蛋白(HbA1c)三种常见临床测量方法之间的一致性。

Assessing agreement between the three common clinical measurement methods of HbA1c.

作者信息

Jalali Mohammad Taha, Bavarsad Samaneh Salehipour, Hesam Saeed, Afsharmanesh Mohammad Reza, Mohammadtaghvaei Narges

机构信息

Hyperlipidemia Research Center, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.

Department of Laboratory Sciences, faculty of Paramedicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran.

出版信息

J Diabetes Metab Disord. 2020 Feb 11;19(1):273-279. doi: 10.1007/s40200-020-00503-6. eCollection 2020 Jun.

Abstract

Reliable measurement of hemoglobin A1c (HbA1c) has great importance in the diagnosis and monitoring of diabetes mellitus. The aim of the present study was to compare the performance parameters of the three common methods of HbA1c assay, including the Roche, Sebia and TOSOH G8 systems. We studied 120 patients referred to a clinical laboratory for HbA1c assay. The blood samples were analyzed with the Roche, Sebia and TOSOH G8 systems based on immunoassay, capillary electrophoresis, and ion-exchange chromatography techniques, respectively. The Spearman and the Passing-Bablok regression,as well as the Bland-Altman plots, were used to compare these methods. For each assay, the patients' classification was evaluated at the three cut-points of 6.5, 7, and 8% and the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the methods were estimated. Our results showed that there were good correlations and agreement between the methods. We found a mean difference of 0.07% for the TOSOH G8 vs. Roche, 0.06% for the TOSOH G8 vs. Sebia and - 0.01% for the Roche vs. Sebia. The methods represented very low bias, indicating the good accuracy of the results. The sensitivity and specificity of the methods were comparable as well. The three methods also performed similarly in the classification of patients at the proposed cut-off points. Based on our results, the Roche, Sebia and TOSOH G8 systems showed a very high level of agreement with comparable performance parameters and yielded similar and accurate classification of diabetic patients. Therefore, these methods can be used interchangeably.

摘要

血红蛋白A1c(HbA1c)的可靠测量在糖尿病的诊断和监测中具有重要意义。本研究的目的是比较HbA1c检测三种常用方法的性能参数,包括罗氏、赛比和东曹G8系统。我们研究了120名转诊至临床实验室进行HbA1c检测的患者。分别基于免疫测定、毛细管电泳和离子交换色谱技术,用罗氏、赛比和东曹G8系统对血样进行分析。采用Spearman和Passing-Bablok回归以及Bland-Altman图来比较这些方法。对于每种检测方法,在6.5%、7%和8%这三个切点处评估患者的分类,并估计这些方法的灵敏度、特异性、阳性预测值(PPV)和阴性预测值(NPV)。我们的结果表明,这些方法之间存在良好的相关性和一致性。我们发现,东曹G8与罗氏相比平均差异为0.07%,东曹G8与赛比相比平均差异为0.06%,罗氏与赛比相比平均差异为 -0.01%。这些方法的偏差非常低,表明结果具有良好的准确性。这些方法的灵敏度和特异性也相当。在建议的切点处对患者进行分类时,这三种方法的表现也相似。基于我们的结果,罗氏、赛比和东曹G8系统显示出非常高的一致性,性能参数相当,对糖尿病患者的分类相似且准确。因此,这些方法可以互换使用。

相似文献

本文引用的文献

8
Standards of medical care in diabetes--2014.2014年糖尿病医疗护理标准
Diabetes Care. 2014 Jan;37 Suppl 1:S14-80. doi: 10.2337/dc14-S014.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验