Suppr超能文献

磁共振成像与锥形束计算机断层扫描在上颌窦植骨评估中的相关性

Correlation between magnetic resonance imaging and cone-beam computed tomography for maxillary sinus graft assessment.

作者信息

Laurino Fernando Antonio Reis, Choi Isabela Goulart Gil, Kim Jun Ho, Gialain Ivan Onone, Ferraço Renato, Haetinger Rainer Guilherme, Pinhata-Baptista Otavio Henrique, Abdala-Junior Reinaldo, Costa Claudio, Cortes Arthur Rodriguez Gonzalez

机构信息

Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil.

Stricto Sensu Research Program on Integrated Dental Sciences, Universidade de Cuiabá, Cuiabá, Brazil.

出版信息

Imaging Sci Dent. 2020 Jun;50(2):93-98. doi: 10.5624/isd.2020.50.2.93. Epub 2020 Jun 18.

Abstract

PURPOSE

Little is known regarding the accuracy of clinical magnetic resonance imaging (MRI) protocols with acceptable scan times in sinus graft assessment. The aim of this study was to evaluate the correlations between MRI and cone-beam computed tomographic (CBCT) measurements of maxillary sinus grafts using 2 different clinical MRI imaging protocols.

MATERIALS AND METHODS

A total of 15 patients who underwent unilateral sinus lift surgery with biphasic calcium phosphate were included in this study. CBCT, T1-weighted MRI, and T2-weighted MRI scans were taken 6 months after sinus lift surgery. Linear measurements of the maximum height and buccolingual width in coronal images, as well as the maximum anteroposterior depth in sagittal images, were performed by 2 trained observers using CBCT and MRI Digital Imaging and Communication in Medicine files. Microcomputed tomography (micro-CT) was also performed to confirm the presence of bone tissue in the grafted area. Correlations between MRI and CBCT measurements were assessed with the Pearson test.

RESULTS

Significant correlations between CBCT and MRI were found for sinus graft height (T1-weighted, r=0.711 and <0.05; T2-weighted, r=0.713 and <0.05), buccolingual width (T1-weighted, r=0.892 and <0.05; T2-weighted, r=0.956 and <0.05), and anteroposterior depth (T1-weighted, r=0.731 and <0.05; T2-weighted, r=0.873 and <0.05). The presence of bone tissue in the grafted areas was confirmed via micro-CT.

CONCLUSION

Both MRI pulse sequences tested can be used for sinus graft measurements, as strong correlations with CBCT were found. However, correlations between T2-weighted MRI and CBCT were slightly higher than those between T1-weighted MRI and CBCT.

摘要

目的

关于在可接受扫描时间的临床磁共振成像(MRI)方案用于鼻窦移植评估的准确性,目前所知甚少。本研究的目的是使用两种不同的临床MRI成像方案评估上颌窦移植的MRI与锥形束计算机断层扫描(CBCT)测量值之间的相关性。

材料与方法

本研究共纳入15例接受双侧磷酸钙单侧鼻窦提升手术的患者。在鼻窦提升手术后6个月进行CBCT、T1加权MRI和T2加权MRI扫描。由两名经过培训的观察者使用CBCT和MRI医学数字成像和通信文件,在冠状位图像上测量最大高度和颊舌宽度的线性尺寸,以及在矢状位图像上测量最大前后深度。还进行了微型计算机断层扫描(micro-CT)以确认移植区域骨组织的存在。使用Pearson检验评估MRI和CBCT测量值之间的相关性。

结果

CBCT与MRI在鼻窦移植高度(T1加权,r = 0.711,P<0.05;T2加权,r = 0.713,P<0.05)、颊舌宽度(T1加权,r = 0.892,P<0.05;T2加权,r = 0.956,P<0.05)和前后深度(T1加权,r = 0.731,P<0.05;T2加权,r = 0.873,P<0.05)方面存在显著相关性。通过micro-CT确认了移植区域骨组织的存在。

结论

所测试的两种MRI脉冲序列均可用于鼻窦移植测量,因为发现它们与CBCT有很强的相关性。然而,T2加权MRI与CBCT之间的相关性略高于T1加权MRI与CBCT之间的相关性。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验