The reliability of a breath-hold protocol to determine cerebrovascular reactivity in adolescents.

机构信息

Children's Health and Exercise Research Centre, Sport and Health Sciences, College of Life and Environmental Sciences, University of Exeter, Exeter, UK.

School of Human Movement and Nutrition Sciences, University of Queensland, Saint Lucia, Queensland, Australia.

出版信息

J Clin Ultrasound. 2020 Nov;48(9):544-552. doi: 10.1002/jcu.22891. Epub 2020 Jun 30.

Abstract

PURPOSE

Cerebrovascular reactivity (CVR) is impaired in adolescents with cardiovascular disease risk factors. A breath-hold test is a noninvasive method of assessing CVR, yet there are no reliability data of this outcome in youth. This study aimed to assess the reliability of a breath-hold protocol to measure CVR in adolescents.

METHODS

Twenty-one 13 to 15 year old adolescents visited the laboratory on two separate occasions, to assess the within-test, within-day and between-day reliability of a breath-hold protocol, consisting of three breath-hold attempts. CVR was defined as the relative increase from baseline in middle cerebral artery mean blood velocity following a maximal breath-hold of up to 30 seconds, quantified via transcranial Doppler ultrasonography.

RESULTS

Mean breath-hold duration and CVR were never significantly correlated (r < .31, P > .08). The within-test coefficient of variation for CVR was 15.2%, with no significant differences across breath-holds (P = .88), so the three breath-hold attempts were averaged for subsequent analyses. The within- and between-day coefficients of variation for CVR were 10.8% and 15.3%, respectively.

CONCLUSIONS

CVR assessed via a three breath-hold protocol can be reliably measured in adolescents, yielding similar within- and between-day reliability. Analyses revealed that breath-hold length and CVR were unrelated, indicating the commonly reported normalization of CVR to breath-hold duration (breath-hold index) may be unnecessary in youth.

摘要

目的

患有心血管疾病危险因素的青少年的脑血管反应性(CVR)受损。屏气试验是评估 CVR 的一种非侵入性方法,但目前尚无该方法在年轻人中可靠性的数据。本研究旨在评估一种用于测量青少年 CVR 的屏气方案的可靠性。

方法

21 名 13 至 15 岁的青少年在两次单独的就诊中评估了屏气方案的日内和日间内测试内可靠性,该方案由三个屏气尝试组成。CVR 定义为通过经颅多普勒超声测量的最大屏气达 30 秒后,大脑中动脉平均血流速度相对于基线的相对增加。

结果

平均屏气时间和 CVR 从未呈显著相关性(r < .31,P > .08)。CVR 的日内测试变异系数为 15.2%,三个屏气尝试之间没有显著差异(P = .88),因此后续分析中平均了三个屏气尝试的结果。CVR 的日内和日间变异系数分别为 10.8%和 15.3%。

结论

通过三个屏气尝试评估的 CVR 在青少年中可以可靠地测量,具有相似的日内和日间可靠性。分析表明,屏气时间的长短与 CVR 无关,这表明通常报道的 CVR 与屏气时间(屏气指数)的归一化在年轻人中可能是不必要的。