高能光子束全脑照射降低头皮剂量的剂量学研究。

Dosimetric study of whole-brain irradiation with high-energy photon beams for dose reduction to the scalp.

机构信息

Department of Radiation Oncology, Tokai University School of Medicine, Isehara, Kanagawa, Japan.

Department of Radiation Oncology, Keio University School of Medicine, Shinjuku, Tokyo, Japan.

出版信息

Br J Radiol. 2020 Oct 1;93(1114):20200159. doi: 10.1259/bjr.20200159. Epub 2020 Jul 21.

Abstract

OBJECTIVE

To evaluate the efficiency of high-energy photons for mitigating alopecia due to whole-brain irradiation (WBRT).

METHODS

Planning CT data from 10 patients who received WBRT were collected. We prepared 4 WBRT plans that used 6 or 15 MV photon beams, with or without use of a field-in-field (FiF) technique, and compared outcomes using a treatment planning system. The primary outcome was dose parameters to the scalp, including the mean dose, maximum dose, and dose received to 50% scalp(D50%). Secondary outcomes were minimum dose to the brain surface.

RESULTS

Using FiF, the mean doses were 24.4-26.0 and 22.4-24.1 Gy, and the maximum doses were 30.5-32.1 and 28.5-30.8 Gy for 6 and 15 MV photon beams, respectively. Without FiF, the mean doses were 24.6-26.9 and 22.6-24.5 Gy, and the maximum doses were 30.8-34.6 and 28.6-32.4 Gy for 6 and 15 MV photon beams. The 15 MV plan resulted in a lower scalp dose for each dose parameter ( < 0.001). Using FiF, the minimum doses to the brain surface for the 6 and 15 MV plans were 28.9 ± 0.440 and 29.0 ± 0.557 Gy, respectively ( = 0.70). Without FiF, the minimum doses to the brain surface for the 6 and 15 MV plans were 28.9 ± 0.456 and 29.0 ± 0.529, respectively ( = 0.66).

CONCLUSION

Compared with the 6 MV plan, the 15 MV plan achieved a lower scalp dose without impairing the brain surface dose.

ADVANCES IN KNOWLEDGE

High-energy photon WBRT may mitigate alopecia of patients who receiving WBRT.

摘要

目的

评估高能光子在减轻全脑照射(WBRT)引起的脱发中的效率。

方法

收集了 10 名接受 WBRT 的患者的计划 CT 数据。我们准备了 4 种 WBRT 计划,使用 6 或 15 MV 光子束,或不使用场内技术(FiF),并使用治疗计划系统比较结果。主要结果是头皮剂量参数,包括平均剂量、最大剂量和头皮 50%接受剂量(D50%)。次要结果是脑表面的最小剂量。

结果

使用 FiF,6 和 15 MV 光子束的平均剂量分别为 24.4-26.0 和 22.4-24.1 Gy,最大剂量分别为 30.5-32.1 和 28.5-30.8 Gy。没有 FiF,6 和 15 MV 光子束的平均剂量分别为 24.6-26.9 和 22.6-24.5 Gy,最大剂量分别为 30.8-34.6 和 28.6-32.4 Gy。15 MV 计划使每个剂量参数的头皮剂量更低(<0.001)。使用 FiF,6 和 15 MV 计划的脑表面最小剂量分别为 28.9 ± 0.440 和 29.0 ± 0.557 Gy(=0.70)。没有 FiF,6 和 15 MV 计划的脑表面最小剂量分别为 28.9 ± 0.456 和 29.0 ± 0.529 Gy(=0.66)。

结论

与 6 MV 计划相比,15 MV 计划在不影响脑表面剂量的情况下,使头皮剂量更低。

知识进步

高能光子 WBRT 可能减轻接受 WBRT 的患者的脱发。

相似文献

3
Evaluation of field-in-field technique for total body irradiation.全身照射野中野技术的评估。
Int J Radiat Oncol Biol Phys. 2012 Aug 1;83(5):1641-8. doi: 10.1016/j.ijrobp.2011.10.045. Epub 2012 Jan 26.

本文引用的文献

1

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验