Suppr超能文献

脐带长度对胎儿循环系统的多普勒评估的影响。

Impact of umbilical cord length on fetal circulatory system by Doppler assessment.

机构信息

Pathology Department, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Bogota, Colombia.

Hospital Universitario San Ignacio, Kra 7 40-62, Bogota, Colombia.

出版信息

J Ultrasound. 2020 Dec;23(4):585-592. doi: 10.1007/s40477-020-00495-2. Epub 2020 Jul 11.

Abstract

INTRODUCTION

Numerous studies have revealed the impact of umbilical cord (UC) length on fetal perfusion; abundant data implicate abnormal UC length to neurological delay and subsequent poor prognoses for fetuses and newborns. Indeed, our group previously developed theoretical approximations that contributed to formulas capable of explaining the impact of UC length on cardiac output.

METHODS

We performed an observational study that measured the pulsatility index and flow velocity in umbilical arteries. A special Doppler measured proximal and distal indexes in both arteries. After birth, medical staff measured complete UC length. We obtained maternal and neonatal outcomes from clinical records.

RESULTS

Our study enrolled 20 pregnant mothers. We found that flow velocities in the two edges were different: fetal edges exhibited greater velocity in the majority of cases; but, when we compared pressure differentials (ΔP), the pulsatility index was significantly related to umbilical cord length.

CONCLUSIONS

Fetal perfusion, welfare, and viability are related to UC function as the conveyor of all fetal volemia. Excessive UC length affects cardiac dynamics and increases peripheral vascular resistance. Further studies could validate routine use of the differential proximal and distal measurements proposed in this article, and their implications in in utero fetal heart function. We also hope that early diagnosis or UC alterations could alert neonatologists and obstetricians to clinical conditions of the fetus.

摘要

简介

许多研究揭示了脐带(UC)长度对胎儿灌注的影响;大量数据表明,UC 长度异常与胎儿和新生儿的神经发育迟缓及预后不良有关。事实上,我们的团队之前已经开发出了理论近似值,这些近似值有助于制定能够解释 UC 长度对心输出量影响的公式。

方法

我们进行了一项观察性研究,测量了脐动脉的搏动指数和血流速度。特殊的多普勒在两条动脉的近端和远端测量了指数。分娩后,医务人员测量了完整的 UC 长度。我们从临床记录中获得了母婴结局。

结果

我们的研究纳入了 20 名孕妇。我们发现,两条边缘的血流速度不同:在大多数情况下,胎儿边缘的速度更快;但是,当我们比较压力差(ΔP)时,搏动指数与脐带长度显著相关。

结论

UC 作为胎儿全血量的输送者,其功能与胎儿灌注、福利和活力有关。UC 过长会影响心脏动力学并增加外周血管阻力。进一步的研究可以验证本文提出的近端和远端差异测量的常规使用及其对胎儿宫内心脏功能的影响。我们还希望早期诊断或 UC 改变可以提醒新生儿科医生和妇产科医生注意胎儿的临床状况。

相似文献

1
Impact of umbilical cord length on fetal circulatory system by Doppler assessment.
J Ultrasound. 2020 Dec;23(4):585-592. doi: 10.1007/s40477-020-00495-2. Epub 2020 Jul 11.
2
Can the difference of Doppler indexes at the different points of the umbilical artery predict to the umbilical cord length?
J Matern Fetal Neonatal Med. 2020 Mar;33(5):847-851. doi: 10.1080/14767058.2018.1506440. Epub 2018 Sep 3.
3
Umbilical cord venous pulsation in normal fetuses and its incidence after 13 weeks of gestation.
Ultrasound Med Biol. 1995;21(4):443-6. doi: 10.1016/0301-5629(94)00150-c.
4
Sonographic atypical vascular coiling of the umbilical cord.
Prenat Diagn. 2005 Jan;25(1):1-6. doi: 10.1002/pd.1043.
5
Fetal arterial redistribution indicating true umbilical cord knot.
Eur J Obstet Gynecol Reprod Biol. 2003 Feb 10;106(2):225-6. doi: 10.1016/s0301-2115(02)00211-7.
7
Relationship between arterial and venous Doppler and perinatal outcome in fetal growth restriction.
Ultrasound Obstet Gynecol. 2000 Oct;16(5):407-13. doi: 10.1046/j.1469-0705.2000.00284.x.
8
Routine assessment of cerebroplacental ratio at 35-37 weeks' gestation in the prediction of adverse perinatal outcome.
Am J Obstet Gynecol. 2019 Jul;221(1):65.e1-65.e18. doi: 10.1016/j.ajog.2019.03.002. Epub 2019 Mar 13.
9
Prenatal color Doppler sonographic evaluation of nuchal encirclement by the umbilical cord.
J Clin Ultrasound. 2003 Nov-Dec;31(9):473-7. doi: 10.1002/jcu.10211.
10
Antenatal umbilical coiling index and Doppler flow characteristics.
Ultrasound Obstet Gynecol. 2006 Oct;28(5):699-703. doi: 10.1002/uog.2745.

引用本文的文献

1
Maternal hypercholesterolemia during gestation is associated with elevated lipid levels of two-day-old neonates.
Mol Cell Biochem. 2024 Feb;479(2):363-371. doi: 10.1007/s11010-023-04739-7. Epub 2023 Apr 19.
2
A misdiagnosed case of a 150-cm umbilical cord coiled twice around the fetal neck with a true cord knot: A rare Syrian case report.
SAGE Open Med Case Rep. 2023 Apr 2;11:2050313X231164858. doi: 10.1177/2050313X231164858. eCollection 2023.
3
Analysis of Risk Factors for Intraoperative Hypotension in Cesarean Section and Poor Prognosis of Neonates.
Appl Bionics Biomech. 2022 Mar 24;2022:2468114. doi: 10.1155/2022/2468114. eCollection 2022.

本文引用的文献

1
Reference charts for umbilical Doppler pulsatility index in fetuses with isolated two-vessel cord.
Arch Gynecol Obstet. 2019 Apr;299(4):947-951. doi: 10.1007/s00404-019-05086-z. Epub 2019 Feb 7.
2
The Placenta in Neonatal Encephalopathy: A Case-Control Study.
J Pediatr. 2018 Nov;202:77-85.e3. doi: 10.1016/j.jpeds.2018.06.005. Epub 2018 Jun 29.
3
Anatomical Pathology of the Umbilical Cord and Its Maternal and Fetal Clinical Associations in 434 Newborns.
Pediatr Dev Pathol. 2018 Sep-Oct;21(5):467-474. doi: 10.1177/1093526618758204. Epub 2018 Feb 20.
4
Screening for Preeclampsia: US Preventive Services Task Force Recommendation Statement.
JAMA. 2017 Apr 25;317(16):1661-1667. doi: 10.1001/jama.2017.3439.
5
Sampling and Definitions of Placental Lesions: Amsterdam Placental Workshop Group Consensus Statement.
Arch Pathol Lab Med. 2016 Jul;140(7):698-713. doi: 10.5858/arpa.2015-0225-CC. Epub 2016 May 25.
6
Umbilical cord and preeclampsia.
J Neonatal Perinatal Med. 2016;9(1):49-57. doi: 10.3233/NPM-16814108.
7
Correlation of Placental Pathology with Perinatal Brain Injury.
Surg Pathol Clin. 2013 Mar;6(1):153-80. doi: 10.1016/j.path.2012.11.005. Epub 2012 Dec 21.
8
Hypertension in pregnancy: natural history and treatment options.
Curr Hypertens Rep. 2015 May;17(5):36. doi: 10.1007/s11906-015-0545-1.
9
Immunohistochemical protein expression profiling of growth- and apoptotic-related factors in relation to umbilical cord length.
Early Hum Dev. 2015 May;91(5):291-7. doi: 10.1016/j.earlhumdev.2015.03.001. Epub 2015 Mar 22.
10
Implementation of a simple method to measure total umbilical cord length.
J Neonatal Perinatal Med. 2014;7(4):269-72. doi: 10.3233/NPM-14814023.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验